[Operate] screen
8
/
52
■ Screen display items (numeric values)
Numeric value
display item
Description
Angle 1
(Rotation angle 1)
Rotation angle setting for temporary tightening. The unit is ° (degrees).
Angle 2
(Rotation angle 2)
Rotation angle setting for loosening. The unit is ° (degrees).
Angle 3
(Rotation angle 3)
Rotation angle setting for additional tightening. The unit is ° (degrees).
Rotation 1
(Rotation speed 1)
Rotation speed setting for temporary tightening. The unit is rpm.
Rotation 2
(Rotation speed 2)
Rotation speed setting for full tightening, loosening, and additional tightening. The unit is rpm.
Trq 1
(Torque 1)
Torque setting that is applied when switching from temporary tightening to full tightening. The unit is
N.m.
Trq 2
(Torque 2)
Limit torque setting for full tightening. The unit is N.m.
Trq 3
(Torque 3)
Limit torque setting for tightening. The unit is N.m.
Cycle TM
(Cycle time)
Time setting for the full set of screw tightening operations. The unit is sec.
An error is displayed if the specified time is exceeded.
Hold TM
(Holding time)
Holding time setting for screw tightening judgment. The unit is ms. * See Chapter 15 "Holding time".
Torque allowance
(Torque judgment
range)
Setting range value for when motor torque value judgment is performed in screw tightening judgment.
The unit is ±%.
Example: When the torque judgment range is ±10% for a torque setting of 1 N.m, the judgment is OK
if the torque is from 0.9 N.m to 1.1 N.m. * See Chapter 16.
Counter (Torque
judgment counter)
Setting for number of times that normal motor torque value is detected, for screw tightening judgment.
The judgment is OK if the number of times that the normal motor torque value is detected is within the
range.
The judgment is NG if the number of times that the normal motor torque value is detected is outside
the range. * See Chapter 16.
Summary of Contents for DCD-40L
Page 1: ...Current Controlled Screwdriver DCD 40L 115W Instruction Manual ET A070 19A HIOS Inc ...
Page 27: ... Operation timing charts 27 52 Pattern 2 ...
Page 28: ... Operation timing charts 28 52 Pattern 3 ...
Page 29: ... Operation timing charts 29 52 Pattern 4 ...
Page 37: ... I O 37 52 Timing chart for normal operations when torque judgment is NG ...
Page 38: ... I O 38 52 Timing chart when emergency stop signal is input ...