background image

              

HIOTH

 

                                        User Manual

 

HIOTH TECHNOLOGY CO.,LTD. 

Technical Information 

 

Compatible with any ZigBee network controller 

 

Local and remote wireless control 

 

Button manual control 

 

Leakage protection, overcurrent protection, short-circuit protection, overvoltage protection, 

under-voltage protection, lightning protection 

Specifications

 

 

Radio protocol: ZigBee

IEEE 802.15.4

 

 

Power supply: 220 V AC 

 

USB Output: 5V 1A 

 

Maximum load current: 10A(2000W)  

 

Working mode: Self-locking 

 

Temperature range

0

60

 

 

Humidity range: ≤95% RH   

 

Installation method: wall-mounted   

 

Dimension

86mm×86mm×35mm 

Installation Instructions 

Smart Plug Installation 

CAUTION:

 Cut off power supply at circuit breaker or fuse before installation to avoid fire, shock 

or death! 

1)

 

As shown in Fig.1, using the screwdriver to pry the gaps on the side of the switch, then open 

Summary of Contents for CT-HAZB1012-KJD

Page 1: ...ding fault fire hazard or overload currents caused by lightning This product has the advantages of leakage pro tection overcurrent protection short circuit protection overvoltage protection under voltage protection lightning protection and so on it can also complete elimination of electrical fire acci dents and prolong the service life of the electric appliances With the advantages of high sensiti...

Page 2: ...on Specifications Radio protocol ZigBee IEEE 802 15 4 Power supply 220 V AC USB Output 5V 1A Maximum load current 10A 2000W Working mode Self locking Temperature range 0 60 Humidity range 95 RH Installation method wall mounted Dimension 86mm 86mm 35mm Installation Instructions Smart Plug Installation CAUTION Cut off power supply at circuit breaker or fuse before installation to avoid fire shock or...

Page 3: ...all wires into right terminals and tighten screws Fig 2 NOTES FOR THE DIAGRAM L terminal for live lead N terminal for neutral lead L1 output terminal of load controlling connected lighting device or other load 4 Install a switch base as shown in Fig 3 Place the touch switch on the wall by securing the bottom onto the junction box with two screws and then mount the touch panel back Fig 3 ...

Page 4: ...r LED on the control panel Fig 4 Including of ZigBee network 1 Connect the power supply 2 Press the Reset button the network status indicator LED Red Light will long on 3 Choose FBee to enter the Network Inclusion mode on the APP then click Save 4 When prompt a message Request Access Success please go to the device list interface and refresh the device list the device will be displayed Reset Butto...

Page 5: ...upply to secure the safety of people and device During installation protect the device from any physical damage by dropping or bumping If happened please contact the supplier for maintenance Keep the device away from acid base and other corrosive solids liquids gases to avoid damage Avoid overexertion during operation to protect device from mechanical damage Prohibit the use of USB interface to la...