Hipo INKJET plotter manual
19
Figure 7-9 the overlapping or separation of nozzles
③
Correction of displacement
If in the process of plotting, there’s the situation of Figure 7-12, you need to
fill in a positive number in the column of correction (See Figure 7-10); The unit
of the figure is mm, accurate to 0.01mm. The figure is normally below 2.5mm.
Repeatedly adjust the number will generate the best effect.
Figure 7-10 correction of displacement
Figure 7-12 fill in a positive number in the column
If in the process of plotting, there’s the situation of Figure 7-13, you need to
fill in a negative number in the column of correction (See Figure 7-10). The unit
of the figure is mm, accurate to 0.01mm. The figure is normally below 2.5mm.
Repeatedly adjust the number will generate the best effect.