3. Assembly and installation procedure HIRO 160 Q
7
3.3 Installation of guide rails
In lift units where the guide rails are fixed to the
wall only, be sure to use through bolts or wall
anchors.
Where guide rails are fixed to the wall, the fixing
points are shown as W1 - W... on the lift unit
drawing.
If the guide rails are to be fixed to concrete, only
approved adhesive anchors or stud bolts must be
used.
When fixing the supports, they must be supported
with a bracket attached to the nearest wall
wherever possible.
The lift unit drawing specifies the distances
between the guide rail and the staircase tread.
Lay the lower end of the guide rail track on the
floor. The lower edge of the guide rail track is
specified in the lift unit drawing from the outer
edge of the staircase tread (zero point).
For lifts with a horizontal travel path, the height
dimension specified is that of the guide rail track.
Adjust the guide rail track with the supports loosely
attached or using a hydraulic jack.
Particular attention must be paid to ensure that the
guide rail track and the supports are properly
anchored.