HIROSE ELECTRIC CO.,LTD.
ETAD-T0652-00
1
3
/6
FORM HC0011-9-2
△
0
2. Applicable Cable
□
1.5D-2W or equivalent
Note: The crimp condition varies with the structure of the cable. Check the cable before use.
3. Harness method
(1)
Strip the cable sheath.
Note: 1.
Refer to “The Crimp Quality Standard Sheet” for the cable-end processing dimensions.
2.
Neatly cut the cable end before processing so that the core conductor, dielectric material,
outer conductor, and sheath will be aligned together.(Make sure that the cable is not
deformed.)
3. Pay utmost attention not to damage the cut edge of the core conductor, dielectric material,
or outer conductor.
(2)
Use the dedicated jig and crimp the center contact.
Note: 1.
Refer to “The Crimp Condition Table” for the crimp height.
Note: 2.
Refer to “The Crimp Quality Standard Sheet” for the crimp work standards.
(3)
Put the cable into the outer contact.
Note: 1.
Check that the direction of the outer contact is correct as shown in the illustration below.
Note: 2. Pay attention not to deform the crimped contact.
Jul.1.2022 Copyright 2022 HIROSE ELECTRIC CO., LTD. All Rights Reserved.