HIROSE ELECTRIC CO.,LTD.
ETAD-T0652-00
1
6
/6
FORM HC0011-9-2
△
0
1
(8)
Use the dedicated jig and crimp the outer contact.
Note: 1.
Refer to “The Crimp Condition Table” for the crimp height.
Note: 2.
Refer to “The Crimp Quality Standard Sheet” for the crimp work standards.
Note: 3. Confirm that the insulator is fixed by the lance of the outer contact.
(9)
Insert the outer contact into the housing.
Note: 1. Coincide the protruding part of the outer contact with the groove of the housing and insert
the outer contact.
Note: 2. Insert the outer contact until the position of the outer contact is fixed by the lance of the
housing.
(10)
Harness work completed
0.4