Based specifications and 
standards:

The devices fulfil the following
specifications and standards: 
– EN 61000-6-2:2001 Generic standards –

Immunity for industrial environments

– EN 55022:1998 + A1:2000 + A2:2003 –

Information technology equipment – 
Radio disturbance characteristics

– EN 60950-1:2001 – Safety of Information

Technology Equipment (ITE)

– EN 61131-2:2003 – Programmable Control-

lers

– FCC 47 CFR Part 15:2004– 

Code of Federal Regulations

– cUL 508:1998 – Underwriters Labratories

Inc. Safety for Industrial Control
Equipment.

Certified devices are marked with a
certification identifier.

7

Notes on CE 
identification

The devices comply with the regula-
tions of the following European
directive:

89/336/EEC
Council Directive on the harmoniza-
tion of the legal regulations of mem-
ber states on electromagnetic com-
patibility (amended by Directives
91/263/EEC, 92/31/EEC and
93/68/EEC).

SPIDER 5TX EEC:
72/245/EEC, 2005/83/EG
Radio interference (electromagnetic
compatibility) in vehicles
Certified devices are marked with a
e1 certification identifier.

The EU declaration of conformity is
kept available for the responsible
authorities in accordance with the
above-mentioned EU directives at:

Hirschmann 
Automation and Control GmbH
Stuttgarter Straße 45-51
D-72654 Neckartenzlingen
T+49-(0)1805-14-1538

The product can be used in the resi-
dential sphere (residential sphere,
business and trade sphere and small
companies) and in the industrial
sphere.
– Interference immunity: 

EN 61000-6-2:2001

– Radio interference level: 

EN 55022:1998 + A1:2000 
+ A2:2003, Class A

z

Warning!

This is a Class A device. This equip-
ment may cause radio interference if

Staff qualification
requirements

Note: 

Qualified personnel, as understood

in this manual and in the warning signs, are
persons who are familiar with the setup,
assembly, startup,  and operation of this
product and are appropriately qualified for
their job. This includes, for example, those
persons who have been:

– trained or directed or authorized to

switch on and off, to ground and to label
power circuits and devices or systems in
accordance with current safety enginee-
ring standards

– trained or directed in the care and use of

appropriate safety equipment in accor-
dance with the current standards of safety
engineering

– trained in providing first aid.

General Safety Instructions

This device is electrically operated.

Adhere strictly to the safety requirements
relating to voltages applied to the device as
described in the operating instructions!

z

Warning!

Failure to observe the information
given in the warnings could result in
serious injury and/or major damage.

Only personnel that have received
appropriate training should operate
this device or work in its immediate
vicinity. The personnel must be fully
familiar with all of the warnings and
maintenance measures in these
operating instructions.

Correct transport, storage, and
assembly as well as careful operati-
on and maintenance are essential in
ensuring safe and reliable operation
of this device.

Use only undamaged parts!

These products are only to be used in

the manner indicated in this version of the
”Description and Operating Instructions”.

Particular attention is to be paid to all

warnings and items of information relating
to safety.

z

Warning!

Any work that may have to be per-
formed on the electrical installation
should be performed by fully quali-
fied technicians only.

z

Warning!

(SPIDER 1TX/1FX...
SPIDER 4TX/1FX...)
LED- or LASER components accor-
ding to IEC 60825-1 (2001): 
CLASS 1 LASER PRODUCT. 
LIGHT EMITTING DIODE - CLASS 1
LED PRODUCT.

used in a residential area; in this
case it is the operator´s responsibili-
ty to take appropriate measures.

The precondition for compliance
with EMC limit values is strict adhe-
rence to the construction guidelines
specified in this description and
operating instructions.

FCC Note:

This equipment has been tested and found
to comply with the limits for a Class A digi-
tal device, persuant to part 15 of the FCC
Rules. These limits are designed to provide
reasonable protection against harmful inter-
ference when the equipment is operated in
a commercial environment. This equipment
generates, uses, and can radiate radio fre-
quency energy and, if not installed and
used in accordance with the instruction
manual, may cause harmful interference to
radio communications. Operation of this
equipment in a residential area is likely to
cause harmful interference in which case
the user will be required to correct the inter-
ference at his own expense.

,

Recycling Note:

After its use, this product has to be
processed as electronic scrap and
disposed of according to the prevai-
ling waste disposal regulations of
your community / district / country /
state.

Summary of Contents for 943 221-001

Page 1: ...1TX 1FX devices have one 10 100 MBit s twisted pair port RJ45 connectors and one 100 MBit s fiber optic port 100BASE FX Duplex SC connector It is possible to connect one data terminal equipments or o...

Page 2: ...alog and technical description and only in conjunction with external devices and components recommen ded or approved by Hirschmann The product can only be operated correctly and safely if it is transp...

Page 3: ...gineering trained in providing first aid General Safety Instructions This device is electrically operated Adhere strictly to the safety requirements relating to voltages applied to the device as descr...

Page 4: ...n autopolarity autocrossing LED display elements Port 5 Port 4 Port 3 Port 2 4 ports 10 100BASE T X RJ45 connectors autonegotiaton autopolarity autocrossing P x P x DA STAT SPIDER 3TX TAP Port 3 Port...

Page 5: ...dresses The SPIDER deletes address entries from the address table which exceed a certain age 300 seconds Note Restarting deletes the learned address entries Tagging IEEE 802 1Q The IEEE 802 1 Q standa...

Page 6: ...the SPIDER to the standard bar and press it down until it locks in position Fit the signal lines Notes The SPIDER is grounded via a pin of the terminal block Do not open the housing The shielding gro...

Page 7: ...air SPIDER 1TX 1FX SPIDER 1TX 1FX SM SPIDER 4TX 1FX 40 C to 70 C 40 F to 158 F SPIDER 4TX 1FX EEC SPIDER 4TX 1FX ST EEC SPIDER 4TX 1FX SM EEC SPIDER 5TX EEC SPIDER 8TX EEC 40 C to 75 C 40 F to 167 F S...

Page 8: ...sockets 10 100 MBit s SPIDER 5TX SPIDER 5TX EEC 5 TP TX ports RJ45 sockets 10 100 MBit s SPIDER 8TX SPIDER 8TX EEC 8 TP TX ports RJ45 sockets 10 100 MBit s Displays Equipment status 1 x green LED P p...

Reviews: