background image

7

5. Technical data

General data

Operating voltage

NEC Class 2 power source 9.6 VDC … 32.0 VDC safety extra-low voltage (SELV/PELV) 
5 A maximum

Buffer time

min. 10 ms at 20.4 VDC

Potential difference between input

Potential difference to input voltage, +24 VDC: 32 VDC

voltage and housing

Potential difference to input voltage, ground: -32 VDC

Current consumption at 24 VDC

2.2 W maximum;  7.5 Btu (IT)/h

SPIDER 3TX-TAP

2.2 W maximum;  7.5 Btu (IT)/h

SPIDER 5TX, SPIDER 5TX EEC

3.9 W maximum;  13.3 Btu (IT)/h

SPIDER 8TX, SPIDER 8TX EEC

3.0 W maximum;  10.2 Btu (IT)/h

SPIDER 1TX/1FX...

3.9 W maximum;  13.3 Btu (IT)/h

SPIDER 4TX/1FX...

Dimensions W x H x D

25 mm x 114 mm x 79 mm

SPIDER 3TX-TAP

(1.0 in x 4.5 in x 3.2 in)

25 mm x 114 mm x 79 mm

SPIDER 5TX, SPIDER 5TX EEC

(1.0 in x 4.5 in x 3.2 in)

40 mm x 114 mm x 79 mm

SPIDER 8TX, SPIDER 8TX EEC

(1.6 in x 4.5 in x 3.2 in)

25 mm x 114 mm x 79 mm

SPIDER 1TX/1FX...

(1.0 in x 4.5 in x 3.2 in)

25 mm x 114 mm x 79 mm

SPIDER 4TX/1FX, SPIDER 4TX/1FX EEC, 

(1.0 in x 4.5 in x 3.2 in)

SPIDER 4TX/1FX-SM EEC

25 mm x 126 mm x 79 mm

SPIDER 4TX/1FX-ST EEC

(1.0 in x 5.0 in x 3.2 in)

Weight

113 g (0.25 lb)

SPIDER 3TX-TAP

113 g (0.25 lb)

SPIDER 5TX, SPIDER 5TX EEC

177 g (0.39 lb)

SPIDER 8TX, SPIDER 8TX EEC

105 g (0.23 lb)

SPIDER 1TX/1FX...

120 g (0.27 lb)

SPIDER 4TX/1FX...

Ambient temperature

0 ºC to + 60 ºC (32 ºF to 140 ºF)

SPIDER 3TX-TAP, SPIDER 5TX, SPIDER 8TX

Surrounding air

SPIDER 1TX/1FX, SPIDER 1TX/1FX-SM
SPIDER 4TX/1FX

-40 ºC to + 70 ºC (-40 ºF to 158 ºF)

SPIDER 4TX/1FX EEC, SPIDER 4TX/1FX-ST EEC, 
SPIDER 4TX/1FX-SM EEC, SPIDER 5TX EEC, 
SPIDER 8TX EEC

-40 ºC to + 75 ºC (-40°F to 167°F)

SPIDER 1TX/1FX EEC, SPIDER 1TX/1FX-SM EEC

Storage temperature

- 40 ºC to + 70 ºC (-40 ºF to 158 ºF)

SPIDER 3TX-TAP, SPIDER 5TX, SPIDER 8TX

Surrounding air

SPIDER 1TX/1FX, SPIDER 1TX/1FX-SM
SPIDER 4TX/1FX

-40 ºC to + 85 ºC (-40 ºF to 185 ºF)

SPIDER 1TX/1FX EEC, SPIDER 1TX/1FX-SM EEC
SPIDER 4TX/1FX EEC, SPIDER 4TX/1FX-ST EEC
SPIDER 4TX/1FX-SM EEC, SPIDER 5TX EEC, 
SPIDER 8TX EEC

Humidity

up to 95% (non condensing)

Atmospheric pressure

up to 2000 m (795 hPa, higher altitudes on demand)

Pollution Degree

2

Laser protectionz

Class 1 conforming to EN 60825-1 (SPIDER 1TX/1FX..., SPIDER 4TX/1FX...)

Protection type

IP 30

Interference proof

Discharge of static electricity

Contact discharge

EN 61000-4-2 Test level 3

Air discharge

EN 61000-4-2 Test level 3

Electromagnetic fields

EN 61000-4-3 Test level 3

Fast transients

EN 61000-4-4 Test level 3

Surge voltage symmetrical

EN 61000-4-5 Test level 2

Surge voltage asymmetrical

EN 61000-4-5 Test level 3

Cable-based RF faults

EN 61000-4-6 Test level 3

EMC emitted immunity

EN 55022

Class A

FCC 47 CFR Part 15

Class A

Stability

Vibration

IEC 60068-2-6 Test FC, testing level in line with EN 61131-2:2003

Shock

IEC 60068-2-27 Test Ea, testing level in line with EN 61131-2:2003

Certifications

cUL 508 / CSA 22.2 No.142

E175531

Network size

TP port 10BASE-T/100BASE-TX

Length of a twisted pair segment

100 m (328 ft) maximum

F/O port 100BASE-FX

Summary of Contents for 943 221-001

Page 1: ...1TX 1FX devices have one 10 100 MBit s twisted pair port RJ45 connectors and one 100 MBit s fiber optic port 100BASE FX Duplex SC connector It is possible to connect one data terminal equipments or o...

Page 2: ...alog and technical description and only in conjunction with external devices and components recommen ded or approved by Hirschmann The product can only be operated correctly and safely if it is transp...

Page 3: ...gineering trained in providing first aid General Safety Instructions This device is electrically operated Adhere strictly to the safety requirements relating to voltages applied to the device as descr...

Page 4: ...n autopolarity autocrossing LED display elements Port 5 Port 4 Port 3 Port 2 4 ports 10 100BASE T X RJ45 connectors autonegotiaton autopolarity autocrossing P x P x DA STAT SPIDER 3TX TAP Port 3 Port...

Page 5: ...dresses The SPIDER deletes address entries from the address table which exceed a certain age 300 seconds Note Restarting deletes the learned address entries Tagging IEEE 802 1Q The IEEE 802 1 Q standa...

Page 6: ...the SPIDER to the standard bar and press it down until it locks in position Fit the signal lines Notes The SPIDER is grounded via a pin of the terminal block Do not open the housing The shielding gro...

Page 7: ...air SPIDER 1TX 1FX SPIDER 1TX 1FX SM SPIDER 4TX 1FX 40 C to 70 C 40 F to 158 F SPIDER 4TX 1FX EEC SPIDER 4TX 1FX ST EEC SPIDER 4TX 1FX SM EEC SPIDER 5TX EEC SPIDER 8TX EEC 40 C to 75 C 40 F to 167 F S...

Page 8: ...sockets 10 100 MBit s SPIDER 5TX SPIDER 5TX EEC 5 TP TX ports RJ45 sockets 10 100 MBit s SPIDER 8TX SPIDER 8TX EEC 8 TP TX ports RJ45 sockets 10 100 MBit s Displays Equipment status 1 x green LED P p...

Reviews: