46
BAT-F, BAT-Rail, BAT54, BAT300
Release 02 07/10
State on delivery: autonegotiation activated.
The socket housing is electrically connected to the bottom panel.
2.13
Installing the BAT-F X2 housing cover
For use in environments with the danger of explosions, the BAT-F X2 device
models have an additional housing cover made of stainless sheet steel.
On delivery, the housing cover is pre-mounted.
Perform the installation in the following steps:
Remove the upper part of the housing cover on the device, as shown in
the following figure (point 1).
Do not try to remove the lower panel of the housing cover from the device.
Screw the device, including the lower panel of the housing cover, to the
mounting surface.
Set up the connections to the device.
Close the housing cover by replacing the upper part of the housing cover.
Fasten the housing cover with four screws, as shown in the following
figure (point 2).
Figure
Pin
Function
1
RD+
Receive Data +
2
RD-
Receive Data -
3
TD+
Transmit Data +
6
TD-
Transmit Data -
4,5,7,8
Not used
Table 5: Pin assignment of a TP/TX interface in MDI-X mode, RJ45 socket
8
7
6
5
4
3
2
1