BAT-F, BAT-Rail, BAT54, BAT300
Release 02 07/10
53
Port Status - Ethernet Port
These LEDs display port-related information.
2.18
Operation element (reset button)
In the AP / AC family devices, the operating elements include a reset button.
2.18.1 Functions
The reset button has two different functions, which are triggered by pressing
the button for different lengths of time:
X
Resetting the configuration (hard reset) – the button is pressed for
more than 5 seconds but less than 10 seconds. All LEDs on the device
light up continuously. When the reset button is released, the device
restarts with the factory settings.
The hard reset can be used, for example, if you have to reconfigure the
device independently of any existing settings, or if no connection to the
device configuration can be made.
X
Device restart (soft reset) – the button is pressed for less than 5 seconds
or more than 10 seconds. The device restarts.
Warning
After the hard reset, the device restarts in the unconfigured state,
and all the settings are lost. Therefore you may want to save the
current configuration of the device before the reset.
2.18.2 BAT-F
In the BAT-F, the reset button (see (1) in the following figure) can be
accessed from outside via a locking screw.
On delivery, the reset button is closed off with a screwable cover cap
(protection class IP67).
LS/DA
(green/yellow LED)
Data, link status
Status of the LAN interfaces
Off
No network device connected
Green
on continuously
Ethernet connection active
Yellow
flickering
Data traffic