V.24 interface (external management)
At the V.24 connection, a serial interface is provided for the local
connection of an external management station (VT100 terminal or PC
with corresponding terminal emulation) or an AutoConfiguration Adapter
ACA 11. This enables you to set up a connection to the Command Line
Interface (CLI) and to the system monitor.
Caution!
Available as an accessory for certain Hirschmann devices,
the AutoConfiguration Adapter ACA21-M12 is not designed to
be used with BAT-F devices.
If you do not adhere to this warning, the ACA21-M12 could be destroyed.
Use the ACA11-M12 if you want to use an AutoConfiguration
Adapter for your BAT-F.
The connector is a 4-pin M12 female connector with A coding.
On delivery, the connector is sealed with a cover cap.
The housing of the M12 socket and the signal connectors are electrically
connected to the functional ground (FE) and to the metal housing of the
device.
VT 100 terminal settings
Data
8 bit
Stopbit
1 bit
Handshake
off
Parity
none
Figure
Pin
Function
1
TX
Transmit data
2
RX
Receive data
3
N.C.
Not connected
4
GND
Ground
Table 6: Pin assignment of the V.24 interface for BAT-F (M12 socket)