56
BAT-F, BAT-Rail, BAT54, BAT300
Release 02 07/10
Note: You will find the order number for the terminal cable, which is
ordered separately, in the ”Technical Data” chapter
(see on page 57
„Technical data“)
.
2.20
Disassembly
To remove the device from the DIN rail, press the device downwards and
pull it out from under the DIN rail.
Figure 22: Removal from the DIN rail
Figure
Pin
Function
1
CTS
Clear to send
2
RTS
Request to send
3
RxD
Receive data
4
RI
Ring indicator
5
TxD
Transmit data
6
DSR
Dataset ready
7
DCD
Data carrier detect
8
DTR
Data terminal ready
U
GND
Ground
Table 7: Pin assignment of the V.24 interface for BAT-Rail (miniDin socket)
1
6
3
4
2
8
5
7
U