EMC
Radio topology BAT...
BAT Client
WLAN access point, bridge, router, point-to-point, client,
client-bridge mode, fixed mesh with RSTP
WLAN client, client-bridge mode
Roaming
BAT...
Seamless handover, IAPP support, IEEE802.11d support,
background scanning for rogue AP detection and fast
roaming
Transmission
power
BAT54
(except for BG/
BGN types)
2.4 GHz 802.11b: +19 dBm @1 and 2 Mbit/s, +19 dBm @
5.5 and 11 Mbit/s, 2.4 GHz 802.11g: +19 dBm @ 6 Mbit/s,
+14 dBm @ 54 Mbit/s,
5 GHz 802.11a/h:+18 dBm @ 6 Mbit/s, +12 dBm @ 54 Mbit/
s with TPC and DFS, transmission power reduction in 1 dB
steps to minimum 0.5 dBm
BAT300
(except for BG/
BGN types)
max. 2.4 GHz 802.11b: +19 dBm @ 1 and 2 MBit/s, +19
dBm @ 5.5 and 11 MBit/s (power output at antenna input);
max. 2.4 GHz power output at antenna input 802.11g: +18
dBm @ 6 to 36 MBit/s, +17 dBm @ 48 MBit/s, +16 dBm @
54 MBit/s; 802.11n: +19 dBm @ 6.5/13 MBit/s (MCS0/8, 20
MHz), +10 dBm @ 65/130 MBit/s (MCS7/15, 20 MHz), +17
dBm @ 15/30 MBit/ s (MCS0/8, 40 MHz), +10 dBm @ 150/
300 MBit/s (MCS7/15, 40 MHz);
max. 5 GHz power output at antenna input 802.11a/h: +18
dBm @ 6 to 24 MBit/s, +17 dBm @ 36 MBit/s, +16 dBm @
48 MBit/s, +15 dBm @ 54 MBit/s; 802.11n: +18 dBm @ 6.5/
13 MBit/s (MCS0/8, 20 MHz), +10 dBm @ 65/130 MBit/s
(MCS7/15, 20 MHz), +17 dBm @ 15/30 MBit/s (MCS0/8, 40
MHz), +10 dBm @ 150/300 MBit/s (MCS7/15, 40 MHz);
min. transmission power reduction via software in 1 dB
steps to min. 0.5 dBm
BAT54 BG/BGN
2.4 GHz 802.11b: +19 dBm @1 and 2 Mbit/s, +19 dBm @
5.5 and 11 Mbit/s, 2.4 GHz 802.11g: +19 dBm @ 6 Mbit/s,
+14 dBm @ 54 Mbit/s
BAT300 BG/BGN max. 2.4 GHz 802.11b: +19 dBm @ 1 and 2 MBit/s, +19
dBm @ 5.5 and 11 MBit/s (power output at antenna input);
max. 2.4 GHz power output at antenna input 802.11g: +18
dBm @ 6 to 36 MBit/s, +17 dBm @ 48 MBit/s, +16 dBm @
54 MBit/s; 802.11n: +19 dBm @ 6.5/13 MBit/s (MCS0/8, 20
MHz), +10 dBm @ 65/130 MBit/s (MCS7/15, 20 MHz), +17
dBm @ 15/30 MBit/ s (MCS0/8, 40 MHz), +10 dBm @ 150/
300 MBit/s (MCS7/15, 40 MHz)
EMC interference
immunity
BAT...
BAT300
-Rail
EN 61000-4-2
Electrostatic discharge
Contact discharge: test level 3
Air discharge: test level 3
6 kV
8 kV
4 kV
8 kV
EN 61000-4-3
Electromagnetic field, test level 3 (80 - 2000 MHz)
10 V/m
3 V/m
EN 61000-4-4
Fast transients (burst), test level 3
- Power line
- Data line
2 kV
1 kV