36
Installation BXS
Release 01 04/2022
7
Technical data
7.1
General data
7.2
Supply voltage
General data
Dimensions
W × H × D
See “Dimension drawings” on page 41.
Weight
BXS30-12TX-EECC-LV-2A
2.25 kg (4.96 lbs)
BXS40-12TX-EECC-LV-2A
BXS30-12TX-EECC-HV-2A
2.15 kg (4.74 lbs)
BXS40-12TX-EECC-HV-2A
BXS32-12TX-EECC-LV-2A
2.37 kg (5.22 lbs)
BXS42-12TX-EECC-LV-2A
BXS32-12TX-EECC-HV-2A
2.63 kg (5.8 lbs)
BXS42-12TX-EECC-HV-2A
Mounting
See “Mounting on a flat surface” on page 27.
Pollution degree
2
Degree of
protection
IP40
Table 7:
General data
Supply voltage with the characteristic value BB
Rated voltage DC:
24 V DC
Voltage range DC incl. maximum
tolerances:
16.8 V DC ... 32 V DC
Rated voltage for rail applications
according to EN 50155
24 V DC
Voltage range including maximum
tolerances for rail applications according
to EN 50155 (permanent)
16.8 V DC ... 30 V DC
Voltage range including maximum
tolerances for rail applications according
to EN 50155 (0.6 × U
N
for 0.1 s; 1.4 × U
N
for 1 s)
14.4 V DC ... 33.6 V DC
Connection type
5-pin, “L”-coded M12 plug
Tightening torque
0.6 Nm (5.3 lb-in)
Wire diameter
min. AWG20 (0.5 mm²)
Power loss buffer
>10 ms at 20.4 V DC
Table 8:
Supply voltage with characteristic value BB
Summary of Contents for BXS