24
Installation EAGLE One
Release 06 12/2018
1.6
Display elements
After the supply voltage is set up, the software starts and initializes itself.
Afterwards, the device performs a self-test.
1.6.1
Device state
These LEDs provide information about conditions which affect the operation
of the whole device.
LED
Display
Color Activity
Meaning
Power Supply voltage
—
None
Supply voltage is too low
Yellow Lights up
Supply voltage 1
or
2 is on
Green Lights up
Supply voltages 1
and
2 are on
Status Device Status
—
None
Device is starting and/or is not ready for
operation
Green Lights up
Device is ready for operation.
Characteristics can be configured
Red
Lights up
The signal contact is open - it is reporting a
detected error.
RR
Router redun-
dancy
—
None
No router redundancy configured.
Green Lights up
The device is in the Router Redundancy
Master mode.
Yellow Long flashing The device is in the Router Redundancy
Backup mode.
Lights up
The device is in the Router Redundancy
Master mode, and the communication with
the backup device is disturbed.
ACA
Storage medium
ACA21-USB
—
None
No ACA connected
Green Lights up
ACA storage medium connected
Flashes 1 time
a period
The device writes to the storage medium.
Flashing 2
times a period
The device reads from the storage medium.
Yellow Lights up
ACA storage medium inoperative