Installation EAGLE One
Release 06 12/2018
7
Supply with DC voltage:
A fuse suitable for DC voltage is located in the plus conductor of the
power supply.
The minus conductor is on ground potential. Otherwise, a fuse is
also located in the minus conductor.
Regarding the properties of this fuse:
See “General technical data”
on page 42.
The wire diameter of the power supply cable is at least 1 mm²
(North America: AWG16) on the supply voltage input.
The cross-section of the protective conductor is the same size as
or bigger than the cross-section of the power supply cables.
The power supply cables used are permitted for the temperature
range required by the application case.
Relevant for North America:
Use 60/75 or 75 °C copper (Cu) wire only.
Internal fuses are triggered only in the case of a detected error in the
device. In case of damage or malfunction of the device, turn off the
supply voltage and return the device to the plant for inspection.
Input/output interfaces
Every
time you connect the electrical conductors, make sure that the fol-
lowing requirements are met:
The electrical wires are voltage-free.
The connected voltage is limited by a current limitation device or a
fuse.
Observe the electrical threshold values for the signal contact.
See “General technical data” on page 42.
Observe the electrical threshold values for the digital input.
See “Digital input” on page 43.
Installation site requirements
Verify that there is at least 4 in (10 cm) of space above and below the
device.
Verify that there is at least 0.8 in (2 cm) of space on the right and left
sides of the device.
Install the device in a fire protected enclosure according to
EN 60950-1.