Basic Settings
[ Basic Settings > Modules ]
21
RM GUI GRS
Release
8.0
09/2019
1.2
Modules
[ Basic Settings > Modules ]
The device lets you install or remove the modules during operation (hot
-
plug).
As long as the
Ethernet module status
column displays the value
configurable
you can configure
the module and save its preferences.
When you replace the module with an identical module, the device applies the settings to the
new module immediately.
When you replace the module with a different type of module, the device applies the factory
settings to the new module.
When you plug a module in an empty slot, the device configures the module with its default
settings. If the slot is inactive, then it remains inactive until you mark the checkbox in the
Active
column. With the port default settings loaded on the module, access to the network is possible.
Install an Ethernet module
Perform the following steps:
Plug the module in the slot.
The device automatically configures the module with the default settings, and detects the
module parameters.
To update the Graphical User Interface, click the button.
The
Ethernet module status
column displays the value
physical
for the installed Ethernet module.
To temporarily save the changes, click the button.
Activate/Deactivate a slot
On a deactivated slot, the device recognizes the installed module and port configuration is possible.
The module establishes no network connections on a deactivated slot.
Perform the following steps:
In the table, highlight the module.
To deactivate the slot and deny network access, unmark the
Active
checkbox.
To activate the slot and allow network access, mark the
Active
checkbox.
To temporarily save the changes, click the button.
Remove an Ethernet module
Perform the following steps:
Remove the module from the slot.
To update the Graphical User Interface, click the button.
The
Ethernet module status
column displays the value
configurable
for the removed module.
In the table, highlight the entry of the removed module.
Click the button and then the
Remove Ethernet module
item.
The
Ethernet module status
column displays the value
remove
for the removed module.
The
Type
column and some other columns display the value
n/a
.
The marked
Active
checkbox indicates that the slot is still active.
To temporarily save the changes, click the button.
Summary of Contents for GREYHOUND GRS1020
Page 8: ......
Page 16: ......
Page 146: ......
Page 232: ......
Page 310: ......
Page 330: ......
Page 338: ...Readers Comments 337 RM GUI GRS Release 8 0 09 2019 ...
Page 339: ......
Page 340: ......
Page 350: ......
Page 354: ......
Page 617: ...Readers Comments 277 UM Config GRS Release 8 0 09 2019 ...
Page 618: ......
Page 619: ......