Switching
[ Switching > L2-Redundancy > FuseNet > Sub Ring ]
226
RM GUI GRS
Release
8.0
09/2019
5.9.5.1 Sub Ring
[ Switching > L2-Redundancy > FuseNet > Sub Ring ]
This dialog lets you set up the device as a subring manager.
The
Sub Ring
function enables you to easily couple network segments to existing redundancy rings.
The subring manager (SRM) couples a subring to an existing ring (base ring).
In the subring you can use any devices that support MRP as ring participants. These devices do
not require a subring manager function.
When setting up subrings, remember the following rules:
The device supports
Link Aggregation
in the subring
No spanning tree on subring ports
Same
MRP domain
on devices within a subring
Different VLANs for base ring and subring
Specify the VLAN settings as follows:
VLAN
X
for base ring
–
on the ring ports of the base ring participants
–
on the base ring ports of the subring manager
VLAN
Y
for subring
–
on the ring ports of the subring participants
–
on the subring ports of the subring manager
Note:
To help avoid loops, only close the redundant line when the settings are specified in every
device participating in the ring.
Operation
Operation
Enables/disables the
Sub Ring
function.
Possible values:
On
The
Sub Ring
function is enabled.
Off
(default setting)
The
Sub Ring
function is disabled.
Information
Table entries (max.)
Displays the maximum number of subrings supported by the device.
Summary of Contents for GREYHOUND GRS1020
Page 8: ......
Page 16: ......
Page 146: ......
Page 232: ......
Page 310: ......
Page 330: ......
Page 338: ...Readers Comments 337 RM GUI GRS Release 8 0 09 2019 ...
Page 339: ......
Page 340: ......
Page 350: ......
Page 354: ......
Page 617: ...Readers Comments 277 UM Config GRS Release 8 0 09 2019 ...
Page 618: ......
Page 619: ......