Diagnostics
[ Diagnostics > Status Configuration > Signal Contact > Signal Contact 1 ]
245
RM GUI GRS
Release
8.0
09/2019
6.1.3.1 Signal Contact 1 / Signal Contact 2
[ Diagnostics > Status Configuration > Signal Contact > Signal Contact 1 ]
In this dialog you specify the trigger conditions for the signal contact.
The signal contact gives you the following options:
Monitoring the correct operation of the device.
Signaling the device status of the device.
Signaling the security status of the device.
Controlling external devices by manually setting the signal contacts.
The device displays detected faults in the
Status
tab and also in the
Basic Settings > System
dialog,
Signal contact status
frame.
The dialog contains the following tabs:
[
Global
]
Configuration
Mode
Specifies which events the signal contact indicates.
Possible values:
Manual setting
(default setting for
Signal Contact 2
, if present)
You use this setting to manually open or close the signal contact, for example to turn on or off
a remote device. See the
Contact
option list.
Monitoring correct operation
(default setting)
Using this setting the signal contact indicates the status of the parameters specified in the table
below.
Device status
Using this setting the signal contact indicates the status of the parameters monitored in the
Diagnostics > Status Configuration > Device Status
dialog. In addition, you can read the status in the
Signal contact status
frame.
Security status
Using this setting the signal contact indicates the status of the parameters monitored in the
Diagnostics > Status Configuration > Security Status
dialog. In addition, you can read the status in
the
Signal contact status
frame.
Device/Security status
Using this setting the signal contact indicates the status of the parameters monitored in the
Diagnostics > Status Configuration > Device Status
and the
Diagnostics > Status Configuration >
Security Status
dialog. In addition, you can read the status in the
Signal contact status
frame.
Contact
Toggles the signal contact manually. The prerequisite is that you select in the
Mode
drop-down list
the value
Manual setting
.
Summary of Contents for GREYHOUND GRS1020
Page 8: ......
Page 16: ......
Page 146: ......
Page 232: ......
Page 310: ......
Page 330: ......
Page 338: ...Readers Comments 337 RM GUI GRS Release 8 0 09 2019 ...
Page 339: ......
Page 340: ......
Page 350: ......
Page 354: ......
Page 617: ...Readers Comments 277 UM Config GRS Release 8 0 09 2019 ...
Page 618: ......
Page 619: ......