Diagnostics
[ Diagnostics > Status Configuration > Signal Contact > Signal Contact 1 ]
247
RM GUI GRS
Release
8.0
09/2019
Possible values:
marked
(default setting)
Monitoring is active.
If the temperature exceeds / falls below the threshold values, then the signal contact opens.
unmarked
Monitoring is inactive.
You specify the temperature thresholds in the
Basic Settings > System
dialog,
Upper temp. limit [°C]
field and
Lower temp. limit [°C]
field.
Ring redundancy
Activates/deactivates the monitoring of the ring redundancy.
Possible values:
marked
Monitoring is active.
The signal contact opens in the following situations:
–
The redundancy function becomes active (loss of redundancy reserve).
–
The device is a normal ring participant and detects an error in its settings.
unmarked
(default setting)
Monitoring is inactive.
Connection errors
Activates/deactivates the monitoring of the link status of the port/interface.
Possible values:
marked
Monitoring is active.
If the link interrupts on a monitored port/interface, then the signal contact opens.
In the
Port
tab, you have the option of selecting the ports/interfaces to be monitored individually.
unmarked
(default setting)
Monitoring is inactive.
Ethernet module removal
Activates/deactivates the monitoring of the modules.
Possible values:
marked
Monitoring is active.
If you remove a module from the device, then the signal contact opens.
Further down, you have the option of selecting the modules to be monitored individually.
unmarked
(default setting)
Monitoring is inactive.
External memory removed
Activates/deactivates the monitoring of the active external memory.
Summary of Contents for GREYHOUND GRS1020
Page 8: ......
Page 16: ......
Page 146: ......
Page 232: ......
Page 310: ......
Page 330: ......
Page 338: ...Readers Comments 337 RM GUI GRS Release 8 0 09 2019 ...
Page 339: ......
Page 340: ......
Page 350: ......
Page 354: ......
Page 617: ...Readers Comments 277 UM Config GRS Release 8 0 09 2019 ...
Page 618: ......
Page 619: ......