Diagnostics
[ Diagnostics > Ports > TP cable diagnosis ]
272
RM GUI GRS
Release
8.0
09/2019
short
Wires in the cable are touching together causing a short circuit.
unknown
The device displays this value for untested cable pairs.
The device displays different values than expected in the following cases:
•
If no cable is connected to the port, then the device displays the value
unknown
instead of
open
.
•
If the port is deactivated, then the device displays the value
short
.
Min. length
Displays the minimum estimated length of the cable in meters.
If the cable length is unknown or in the
Information
frame the
Status
field displays the value
active
,
failure
or
uninitialized
, then the device displays the value
0
.
Max. length
Displays the maximum estimated length of the cable in meters.
If the cable length is unknown or in the
Information
frame the
Status
field displays the value
active
,
failure
or
uninitialized
, then the device displays the value
0
.
Distance [m]
Displays the estimated distance in meters from the end of the cable to the failure location.
If the cable length is unknown or in the
Information
frame the
Status
field displays the value
active
,
failure
or
uninitialized
, then the device displays the value
0
.
Buttons
You find the description of the standard buttons in section
Start cable diagnosis...
Opens the
Select port
dialog.
In the
Port
drop-down list you select the port to be tested. Use for copper-based ports only.
To initiate the cable test on the selected port, click the
Ok
button.
Summary of Contents for GREYHOUND GRS1020
Page 8: ......
Page 16: ......
Page 146: ......
Page 232: ......
Page 310: ......
Page 330: ......
Page 338: ...Readers Comments 337 RM GUI GRS Release 8 0 09 2019 ...
Page 339: ......
Page 340: ......
Page 350: ......
Page 354: ......
Page 617: ...Readers Comments 277 UM Config GRS Release 8 0 09 2019 ...
Page 618: ......
Page 619: ......