Diagnostics
[ Diagnostics > Ports > Port Monitor ]
279
RM GUI GRS
Release
8.0
09/2019
[
CRC/Fragments
]
In this tab, you specify individually for every port the following settings:
The fragment error rate.
The period during which the
Port Monitor
function monitors a parameter to detect discrepancies.
You also see the fragment error rate that the device has detected up to now.
The
Port Monitor
function monitors those ports for which the checkbox in the
CRC/Fragments on
column is marked on the
Global
tab.
Table
Port
Displays the port number.
Sampling interval [s]
Specifies in seconds, the period during which the
Port Monitor
function monitors a parameter to
detect discrepancies.
Possible values:
5..180
(default setting:
10
)
CRC/Fragments count [ppm]
Specifies the fragment error rate (in parts per million).
If the
Port Monitor
function detects this fragment error rate in the monitored period, then the device
performs the specified action.
Possible values:
1..1000000
(default setting:
1000
)
Last active interval [ppm]
Displays the fragment error rate that the device has detected during the period that has elapsed.
Total [ppm]
Displays the fragment error rate that the device has detected since the port was enabled.
Summary of Contents for GREYHOUND GRS1020
Page 8: ......
Page 16: ......
Page 146: ......
Page 232: ......
Page 310: ......
Page 330: ......
Page 338: ...Readers Comments 337 RM GUI GRS Release 8 0 09 2019 ...
Page 339: ......
Page 340: ......
Page 350: ......
Page 354: ......
Page 617: ...Readers Comments 277 UM Config GRS Release 8 0 09 2019 ...
Page 618: ......
Page 619: ......