Diagnostics
[ Diagnostics > Ports > Auto-Disable ]
285
RM GUI GRS
Release
8.0
09/2019
6.4.4
Auto-Disable
[ Diagnostics > Ports > Auto-Disable ]
The
Auto-Disable
function lets you disable monitored ports automatically and enable them again as
you desire.
For example, the
Port Monitor
function and selected functions in the
Network Security
menu use the
Auto-Disable
function to disable ports if monitored parameters are exceeded.
If the parameters are no longer being exceeded, then the
Auto-Disable
function enables the relevant
port again after the specified waiting period.
The dialog contains the following tabs:
[
Port
]
This tab displays which ports are currently disabled due to the parameters being exceeded. If the
parameters are no longer being exceeded and you specify a waiting period in the
Reset timer [s]
column, then the
Auto-Disable
function automatically enables the relevant port again.
Table
Port
Displays the port number.
Reset timer [s]
Specifies the waiting period in seconds, after which the
Auto-Disable
function enables the port again.
Possible values:
0
(default setting)
The timer is inactive. The port remains disabled.
30..4294967295
If the parameters are no longer being exceeded, then the
Auto-Disable
function enables the port
again after the waiting period specified here.
Error time
Displays when the device disabled the port due to the parameters being exceeded.
Remaining time [s]
Displays the remaining time in seconds, until the
Auto-Disable
function enables the port again.
Component
Displays the software component in the device that disabled the port.
Summary of Contents for GREYHOUND GRS1020
Page 8: ......
Page 16: ......
Page 146: ......
Page 232: ......
Page 310: ......
Page 330: ......
Page 338: ...Readers Comments 337 RM GUI GRS Release 8 0 09 2019 ...
Page 339: ......
Page 340: ......
Page 350: ......
Page 354: ......
Page 617: ...Readers Comments 277 UM Config GRS Release 8 0 09 2019 ...
Page 618: ......
Page 619: ......