Synchronizing the system time in the network
9.1
Basic settings
108
UM Config GRS
Release
8.0
09/2019
9.1.2
Automatic daylight saving time changeover
When you operate the device in a time zone in which there is a summer time change, you set up
the automatic daylight saving time changeover on the
Daylight saving time
tab.
When daylight saving time is enabled, the device sets the local system time forward by 1 hour at
the beginning of daylight saving time. At the end of daylight saving time, the device sets the local
system time back again by 1 hour.
Perform the following steps:
Open the
Time > Basic Settings
dialog,
Daylight saving time
tab.
To select a preset profile for the start and end of daylight saving time, click the
Profile...
button in the
Operation
frame.
When no matching daylight saving time profile is available, you specify the changeover
times in the
Summertime begin
and
Summertime end
fields.
For both time points, you specify the month, the week within this month, the weekday, and
the time of day.
To enable the function, select the
On
radio button in the
Operation
frame.
To save the changes temporarily, click the button.
enable
Change to the Privileged EXEC mode.
configure
Change to the Configuration mode.
clock summer-time mode
<disable|recurring|eu|usa>
Configure the automatic daylight saving time
changeover: enable/disable or activate with a
profile.
clock summer-time recurring start
Enter the start time for the changeover.
clock summer-time recurring end
Enter the end time for the changeover.
save
Save the settings in the non-volatile memory (
nvm
)
in the “selected” configuration profile.
Summary of Contents for GREYHOUND GRS1020
Page 8: ......
Page 16: ......
Page 146: ......
Page 232: ......
Page 310: ......
Page 330: ......
Page 338: ...Readers Comments 337 RM GUI GRS Release 8 0 09 2019 ...
Page 339: ......
Page 340: ......
Page 350: ......
Page 354: ......
Page 617: ...Readers Comments 277 UM Config GRS Release 8 0 09 2019 ...
Page 618: ......
Page 619: ......