Network load control
10.5
Flow control
132
UM Config GRS
Release
8.0
09/2019
Flow Control with a full duplex link
In the example, there is a fullduplex link between Workstation 2 and the device.
Before the send queue of port 2 overflows, the device sends a request to Workstation 2 to include
a small break in the sending transmission.
10.5.2
Setting up the Flow Control
Perform the following steps:
Note:
When you are using a redundancy function, you deactivate the flow control on the
participating ports. If the flow control and the redundancy function are active at the same time, it is
possible that the redundancy function operates differently than intended.
Open the
Switching > Global
dialog.
Mark the
Flow control
checkbox.
With this setting you enable flow control in the device.
Open the
Basic Settings > Port
dialog,
Configuration
tab.
To enable the Flow Control on a port, mark the checkbox in the
Flow control
column.
To save the changes temporarily, click the button.