Device Security
[ Device Security > User Management ]
68
RM GUI GRS
Release
8.0
09/2019
Table
Every user requires an active user account to gain access to the device management. The table
lets you set up and manage user accounts.
To change settings, click the desired parameter in the table and modify the value.
User name
Displays the name of the user account.
To create a new user account, click the button.
Active
Activates/deactivates the user account.
Possible values:
marked
The user account is active. The device accepts the login of a user with this user name.
unmarked
(default setting)
The user account is inactive. The device rejects the login of a user with this user name.
When one user account exists with the
administrator
access role, this user account is constantly
active.
Password
Displays ***** (asterisks) instead of the password with which the user logs in. To change the
password, click the relevant field.
Possible values:
Alphanumeric ASCII character string with 6..64 characters
The following characters are allowed:
–
a..z
–
A..Z
–
0..9
–
!#$%&'()*+,-./:;<=>?@[\]^_`{}~
The minimum length of the password is specified in the
Configuration
frame. The device
differentiates between upper and lower case.
If the checkbox in the
Policy check
column is marked, then the device checks the password
according to the policy specified in the
Password policy
frame.
The device constantly checks the minimum length of the password, even if the checkbox in the
Policy check
column is
unmarked
.
Role
Specifies the user role that regulates the access of the user to the individual functions of the device.
Summary of Contents for GREYHOUND GRS1020
Page 8: ......
Page 16: ......
Page 146: ......
Page 232: ......
Page 310: ......
Page 330: ......
Page 338: ...Readers Comments 337 RM GUI GRS Release 8 0 09 2019 ...
Page 339: ......
Page 340: ......
Page 350: ......
Page 354: ......
Page 617: ...Readers Comments 277 UM Config GRS Release 8 0 09 2019 ...
Page 618: ......
Page 619: ......