Device Security
[ Device Security > Management Access > CLI ]
92
RM GUI GRS
Release
8.0
09/2019
3.3.4
Command Line Interface
[ Device Security > Management Access > CLI ]
In this dialog, you specify settings for the Command Line Interface. You find detailed information
about the Command Line Interface in the “Command Line Interface” reference manual.
The dialog contains the following tabs:
[
Global
]
This tab lets you change the prompt in the Command Line Interface and specify the automatic
closing of sessions through the serial interface when they have been inactive.
The device has the following serial interfaces.
V.24 interface
Configuration
Login prompt
Specifies the character string that the device displays in the Command Line Interface at the start of
every command line.
Possible values:
Alphanumeric ASCII character string with 0..128 characters
(
0x20..0x7E
) including space characters
Wildcards
–
%d
date
–
%i
IP address
–
%m
MAC address
–
%p
product name
–
%t
time
Default setting:
(GRS)
Changes to this setting are immediately effective in the active Command Line Interface session.
Serial interface timeout [min]
Specifies the time in minutes after which the device automatically closes the session of a logged
on user in the Command Line Interface via the serial interface when it has been inactive.
Possible values:
0..160
(default setting:
5
)
The value
0
deactivates the function, and the user remains logged on when inactive.
A change in the value takes effect the next time a user logs on to the device.
For Telnet and SSH, you specify the timeout in the
Device Security > Management Access > Server
dialog.
Summary of Contents for GREYHOUND GRS1020
Page 8: ......
Page 16: ......
Page 146: ......
Page 232: ......
Page 310: ......
Page 330: ......
Page 338: ...Readers Comments 337 RM GUI GRS Release 8 0 09 2019 ...
Page 339: ......
Page 340: ......
Page 350: ......
Page 354: ......
Page 617: ...Readers Comments 277 UM Config GRS Release 8 0 09 2019 ...
Page 618: ......
Page 619: ......