User interfaces
1.3
System monitor
40
UM Config GRS
Release
8.0
09/2019
1.3
System monitor
The System Monitor lets you set basic operating parameters before starting the operating system.
1.3.1
Functional scope
In the System Monitor, you carry out the following tasks, for example:
Managing the operating system and verifying the software image
Updating the operating system
Starting the operating system
Deleting configuration profiles, resetting the device to the factory defaults
Checking boot code information
1.3.2
Starting the System Monitor
Prerequisite:
Terminal cable for connecting the device to your PC (available as an optional accessory).
PC with VT100 terminal emulation (such as the
PuTTY
program) or serial terminal
Perform the following steps:
Use the terminal cable to connect the serial interface of the device with the COM port of the PC.
Start the VT100 terminal emulation on the PC.
Specify the following transmission parameters:
Set up a connection to the device.
Turn on the device. When the device is already on, reboot it.
The screen displays the following message after rebooting:
Press <1> to enter System Monitor 1.
Press the <1> key within 3 seconds.
The device starts the System Monitor. The screen displays the following view:
VT 100 terminal settings
Speed
9600 bit/s
Data
8 bit
Stopbit
1 bit
Handshake
off
Parity
none
Summary of Contents for GREYHOUND GRS1020
Page 8: ......
Page 16: ......
Page 146: ......
Page 232: ......
Page 310: ......
Page 330: ......
Page 338: ...Readers Comments 337 RM GUI GRS Release 8 0 09 2019 ...
Page 339: ......
Page 340: ......
Page 350: ......
Page 354: ......
Page 617: ...Readers Comments 277 UM Config GRS Release 8 0 09 2019 ...
Page 618: ......
Page 619: ......