MACH 4002
Release 1.0 10/05
15
You connect the M4-POWER power unit to the M4-POWER connection on
the back of the MACH 4002 device using exclusively the power supply cable
supplied with the M4-P-xx slide-in power units.
Fig. 2:
M4-POWER power unit chassis with up to 3 slide-in power units
U
Slide-in power units for M4-POWER power unit chassis
D
M4-P-AC/DC 300W
D
M4-P-24VDC 300W, 2 inputs for redundant power supply
D
M4-P-48VDC 300W, 2 inputs for redundant power supply
see
“Order numbers/Product name” on page 37
Note:
The slide-in power units of the switch chassis cannot be used for the
power unit chassis.
1.3
Fan plug-in unit M4-AIR
The M4-AIR fan input is located on the left of the front side of the MACH 4002
chassis. The fan can be replaced during running operation (see
the M4-AIR fan plug-in unit (if required)” on page 25
Power unit 1 Power unit 2 Power unit 3
P
P1
P2
P3
P4
RM
RL1
RL2
FAN
RUN
L/D
FDX
1000
AN
TP/FO
RING
PORT STBY
LED
TEST
2
1
1
2
3
4
LED
MEDIA SLOTS
M4-AIR
SLOT.PORT