34
MACH 4002
Release 1.0 10/05
3
Technical data
General data
1)
NEC Class 2 power source safety extra-low voltage (SELV/PELV)
2)
The 0V connectors within a DC module (M4-...-...VDC 300W) are connected to
each other
Dimensions
MACH 4002
W x H x D: 480 mm x 88 mm x 435 mm
Assembly
MACH 4002
M4-POWER
19" rack
19" rack
Weight
MACH 4002
7.5 kg
Voltage supply
MACH 4002
M4-S-xx power supply or power unit chassis
M4-POWER with M4-P-xx power supply,
please order separately
Operating voltage M4-S-AC/DC 300W
M4-S-24VDC 300W
M4-S-48VDC 300W
100-240 VAC, 120-350 VDC
24 VDC (19.2 V - 32 V)
1)
48 VDC (38.4 V - 60 V)
1)
M4-P-AC/DC 300W
M4-P-24VDC 300W
M4-P-48VDC 300W
100-240 VAC, 120-350 VDC
24 VDC (19.2 V - 32 V)
1)
48 VDC (38.4 V - 60 V)
1)
Buffer time
M4-P-AC/DC 300W
M4-...-24VDC 300W
M4-...-48VDC 300W
1/2 mains period minimum
10 ms at 20.4 VDC minimum
10 ms at 40.8 VDC minimum
Current
consumption
M4-S-AC/DC 300W
M4-S-24VDC 300W
M4-S-48VDC 300W
1.8 A (230 VAC) max., 4.2 A (110 VAC) max.
21.0 A (24 VDC) maximum
10.1 A (48 VDC) maximum
M4-P-AC/DC 300W
M4-P-24VDC 300W
M4-P-48VDC 300W
1.8 A (230 VAC) max., 4.2 A (110 VAC) max.
21.0 A (24 VDC) maximum
10.1 A (48 VDC) maximum
Switch-on current M4-S-AC/DC 300W
M4-P-AC/DC 300W
typ. <40 A at 265 VAC and cold start
typ. <40 A at 265 VAC and cold start
Overload current
protection at input
non-changeable fuse
Potential difference
between input vol-
tage and housing
M4-...-...VDC 300W
Potential difference to input voltage
+24 VDC/ +48VDC: 60 VDC
Potential difference to input voltage 0V: 60 VDC
2)
Surrounding
Storage temperature
Humidity
Atmospheric pressure
Surrounding air: -25 °C to +70 °C
10% to 95% (non condensing)
up to 2.000 m (795 hPa), higher altitudes on
demand
Operating tempe-
rature
MACH 4002
M4-S-xx
M4-P-xx
M-SFP-xx/xx
M-FAST SFP-xx/xx
M4-AIR
M4-8TP-RJ45
M4-FAST 8-SFP
0°C to 50°C
0°C to 50°C
0°C to 50°C
0°C to 60°C
0°C to 60°C
0°C to 50°C
0°C to 50°C
0°C to 50°C
Pollution degree
2
Protection types
Laser protection
Protection types
Class 1 conforming to EN 60825-1 (2001)
IP 20
Summary of Contents for MACH 4002 48+4G
Page 40: ...40 MACH 4002 Release 1 0 10 05 ...
Page 42: ... ...