operation is irrelevant with room temperatures.
3.1.3 If a remote signal has been received during the emergency run, the machine
will operate upon the command of such a remote signal.
3.2 Operator-machine communication
3.2.1 The air conditioner has a thermal sensor to detect room temperatures. Some
remote controller is equipped with a thermal sensor (Such remote controller has
the function of man-machine communication. For details, refer to the section for
the remote controller). In addition, there is a thermal sensor at the indoor air inlet.
In the case where the remote controller is equipped with a thermal sensor, the
default setting for room temperatures is subject to the detection by the remote
controller. The remote controller detects the room temperature once every 20
seconds, and automatically transmits a signal at an interval of 3 minutes or when
a change in the room temperature is detected. If the indoor control unit has not
received a remote signal for more than 10 minutes, the control function will be
automatically switched over to the thermal sensor on the indoor unit.
3.2.2 Neither the turning on nor turning off operation will cancel the
operator-machine communication function.
3.2.3 In default, the air conditioner is set to start the operator-machine
communication function.
3.3 Timer function
3.3.1 Timer on: When set to start in a time by the remote controller, the air
conditioner starts in the timer on condition. When the set time is up, the air
conditioner will turn on and operates in the preset conditions after receiving a
signal from the remote controller. If the air conditioner has not received a signal
from the remote controller when the set time is up, it will automatically start and
operate in the preset conditions.
3.3.2 Timer off: When set to stop in a set time by the remote controller, the air
conditioner will start in the timer off condition. When the set time is up, the air
conditioner will turn off after receiving a signal from the remote controller. If the air
conditioner has not received a signal from the remote controller when the set time
is up, it will turn off automatically.
3.3.3 Neither the turning on nor turning off operation will cancel the timer function
(Some remote controller has a simple one-hour timer off function and excludes
this operation).
3.4 Sleep
3.4.1 In the heating, cooling or dehumidifying mode, press the “Sleep” button on
the remote controller to start or cancel the sleep function in turn, and at the same
time the sleep icon on the display screen will be on or off accordingly.
3.4.2 According to the different needs, there are four different sleep modes to
choose. During the time of sleep mode, the set temperature will change
automatically.
3.4.3 In default, the setting is to cancel the sleep function. Turning off the unit will