Dehumidifying area I: Operation at the frequency in the range (30 – 80 Hz)
according to
Δ
t (T
indoor ambient
-T
set
).
Δ
t(
℃
)
f(Hz)
0 30
0.5 30
1 40
1.5 50
≥
2 60
Efficient 80
Dehumidifying area II: The compressor stops for 5 minutes and operat es for 5
minutes at the lowest frequency.
Dehumidifying area III: The compressor stops.
3.10. Air Blowing mode
The outdoor unit does not work while the indoor fan runs with the fan speed
selectable at the auto, low, medium and high speeds.
When being auto, the fan speed is determined in the cooling mode (with the
temperature setting of 24
0
C in default).
The high, medium and low fan speeds are same with that in the cooling mode.
3.11 Compressor operating state indication
When the compressor is in operation, The 3 LED indicator lights on the control
panel of the outdoor unit indicates the causes of the restriction on the
Time
I
II
III
Indoor Ambient Temperature