7-1.
Trouble alarm
Trouble List
Indication on the outdoor unit
When the compressor is interrupted, the outdoor LEDs are used to
indicate the troubles listed below:
Symbols for indicator lights:
★
: ON
Ο
: flashing
×
: OFF
LED1 LED2 LED3
Troubles
1
×
×
×
Normal
2
×
×
★
Room temperature sensor short-circuited, open
circuited or the corresponding test circuit in trouble
3
×
★
×
Indoor heat exchanger temperature sensor
short-circuited, open circuited or the corresponding
test circuit in trouble
4
★
×
×
Compressor temperature sensor short-circuited,
open circuited or the corresponding test circuit in
trouble
5
★
×
★
Outdoor heat exchanger temperature sensor
short-circuited, open circuited or the corresponding
test circuit in trouble
6
★
★
×
Outdoor atmosphere temperature sensor
short-circuited, open circuited or the corresponding
test circuit in trouble
9
×
×
Ο
Signal communication abnormal (indoor – outdoor)
10
×
Ο
×
Power module (IPM)protection
11
★
Ο
★
Maximum current control
12
★
Ο
×
Current overload control
13
×
Ο
★
Compressor discharge temperature too high
14
★
★
Ο
Over and under-voltage control
18
×
★
Ο
Compressor housing temperature too high
19
★
★
★
Outdoor memory in trouble
20
×
Ο
Ο
Indoor fan motor in trouble
22
Ο
Ο
×
DC compressor fails to start
23
Ο
×
Ο
DC compressor out of step
Indication by the indoor unit
Press the high power for 4 times in a row and the trouble codes
listed below will be displayed.
0
No trouble
16
Anti-freeze or overload control
1
Outdoor coil temperature sensor
in trouble
18
DC compressor fails to start
2
Compressor temperature sensor
in trouble
19
DC compressor out of step
3
Voltage transformer in trouble
4
Current transformer in trouble