8-2.Check parts unit
1. INDOOR FAN MOTOR
.MOTOR EXAMINE AND REPAIR
Circuit diagram
BLACK
WHITE
M
A
Vcc
GND
Vout
BROWN
BLACK
YELLOW
WINDING
" "
" "
M The main winding
A The auxiliar y winding
Capacitor
Hot protector 100
℃
Test in resistance.
TOOL: Multimeter.
Test the resistance of the main winding. The indoor fan motor is fault if the
resistance of main winding 0(short circuit)or
∞(
open circuit
)
.
Test in voltage
TOOL: Multimeter.
Insert screwdriver into to rotate indoor fan motor slowly for 1 revolution or
over,and measure voltage “YELLOW” and “GND” on motor. The voltage repeat
0V DC and 5V DC.
Notes:
1) Please don’t hold motor by lead wires.
2) Please don’t plug IN/OUT the motor connector while power ON.
3) Please don’t drop .Hurl or dump motor against hard material.Malfunction may not
be observed at early stage after such shock.But it may be found later,This type of
mishandling void our warranty.
2. OUTDOOR FAN MOTOR
Circuit diagram
BROWN
WHITE
A2
M
PINK
WINDING
" "
" "
M The main winding
A The auxiliary winding
Capacitor
Hot protector 130
℃
PURPLE
YELLOW
A1
A3
Winding resistance ( at 20 )
℃
(
WHITE—BROWN
)
M: 178
Ω
(WHITE—PINK)A: 171
Ω
MOTOR EXAMINE AND REPAIR
Test in resistance.
TOOL: Multimeter.
Test the resistance of the main winding. The indoor fan motor is fault if the resistance
of main winding 0(short circuit)or
∞
(
open circuit
)
.
Notes: 1) Please don’t hold motor by lead wires.
2
)
lease don’t plug IN/OUT the motor connector while power ON.
3
)
lease don’t drop hurl or dump motor against hard material.Malfunction may not be
observed at early stage after such shock.But it may be found later,This type of
mishandling void our warranty.