2-1. Unit specifications
NOTE :Test conditions
:
Cooling : Indoor: DB27
℃
/ WB19
℃
Outdoor: DB35
℃
/ WB24
℃
Heating:
Indoor: DB20
℃
/ WB15
℃
Outdoor: DB7
℃
/ WB 6
℃
Model AS-09UR4SGN
PQ
Function Cooling
Heating
Power supply
a.c 220V~230V/50Hz
BTU 9000 12000
Capacity
kW 2.6 3.2
Dehumidification l
/h
1.0
—-
Capacity
Air flow
m
3
/h 480
530
Rated current
A
3.6
4.5
MAX. current
A
8.0
10.0
Rated input
kW
0.76
0.88
Electrical data
MAX. input
kW
1.50
1.85
EER/COP 3.42
3.64
MAX.operating
pressure
High
MP
4.15
Indoor unit
L
×
W
×
H
cm
75
×
19
×
25
Net size
Outdoor unit
L
×
W
×
H
cm
80
×
26
×
57
Indoor unit
L
×
W
×
H
cm
84
×
27
×
31
Package size
Outdoor unit
L
×
W
×
H
cm
95
×
37
×
65
Net weight
Indoor unit / Outdoor unit
kg
9.5/34.0
Gross weight
Indoor unit / Outdoor unit
kg
11.5/38.5
Liquid pipe
mm
6.35
Gas pipe
mm
9.52
Refrigerant
piping
Connection method
Flared
Indoor unit
dB
40
Sound level
(Hi)
Outdoor unit
dB
52
Indoor unit
rpm
800/1000/1250
Fan speed
(Hi)
Outdoor unit
rpm
540/620/800
Indoor unit
3
Fan speed
regulator
Outdoor unit
1
Refrigerant filling
capacity(R410A)
kg 0.72
Special
remarks
Throttle mode
CAPILLARY
第 4/51页