5-3-1-3 If a remote signal has been received during the emergency run, the machine will
operate upon the command of such a remote signal.
5-3-2 Operator-machine communication
5-3-2-1 The air conditioner has a thermal sensor to detect room temperatures. Some remote
controller is equipped with a thermal sensor (Such remote controller has the function of
man-machine communication. For details, refer to the section for the remote controller). In
addition, there is a thermal sensor at the indoor air inlet. In the case where the remote
controller is equipped with a thermal sensor, the default setting for room temperatures is
subject to the detection by the remote controller. The remote controller detects the room
temperature once every 20 seconds, and automatically transmits a signal at an interval of 3
minutes or when a change in the room temperature is detected. If the indoor control unit has
not received a remote signal for more than 10 minutes, the control function will be
automatically switched over to the thermal sensor on the indoor unit.
5-3-2-2 Neither the turning on nor turning off operation will cancel the operator-machine
communication function.
5-3-2-3 In default, the air conditioner is set to start the operator-machine communication
function.
5-3-3 Timer function
5-3-3-1 Timer on: When set to start in a time by the remote controller, the air conditioner starts
in the timer on condition. When the set time is up, the air conditioner will turn on and operates
in the preset conditions after receiving a signal from the remote controller. If the air conditioner
has not received a signal from the remote controller when the set time is up, it will
automatically start and operate in the preset conditions.
5-3-3-2 Timer off: When set to stop in a set time by the remote controller, the air conditioner
will start in the timer off condition. When the set time is up, the air conditioner will turn off after
receiving a signal from the remote controller. If the air conditioner has not received a signal
from the remote controller when the set time is up, it will turn off automatically.
5-3-3-3 Neither the turning on nor turning off operation will cancel the timer function (Some
remote controller has a simple one-hour timer off function and excludes this operation).
5-3-4 Sleep
5-3-4-1 In the heating, cooling or dehumidifying mode, press the “Sleep” button on the remote
Summary of Contents for AS-09UR4SVNVG1 (UP1)
Page 1: ...AS 09UR4SVNVG1 UP1 AS 12UR4SVNVG1 UP1...
Page 8: ...3 3 I IN NS ST TA AL LL LA AT TI IO ON N 7 5 Outdoor unit feet distance...
Page 9: ...4 4 E EL LE EC CT TR RI IC CA AL L D DA AT TA A 7 4 1 Electrical wiring diagrams 4 1 1 INDOOR...
Page 10: ...4 4 E EL LE EC CT TR RI IC CA AL L D DA AT TA A 8 4 1 2 OUTDOOR...