When the appliance turn in the anti-cold air system in the Extra-LOW (Tapped motor set in LOW,
sic passim) during the compressor operation, the louver swang to the Cool air protection position, the
louver recovers to the original position after the air volume change to LOW. When the room
temperature reach to the setting temperature, the compressor will be turn off, and the air flow
change to LOW, the louver swang to the Cool air protective position to prevent the air drop into
human body directly; when the indoor pipe coil temperature drop continuously, it will turn in the
Cooling air protective system in the Extra-LOW or stop the fan motor.
The indoor fan motor is only controlled by the signal of indoor pipe coil temperature, no matter
the compressor turn ON/OFF, even the appliance turn in Heat mode at first time.
The indoor fan motor will operate according to the different setting(High, Median, Low and
Automatic) by the remote control, but the anti-cold air system is prior.
When the appliance run in the Heat mode with the Automatic setting at first time, the fan speed
will be in the LOW setting, and the operation diagram is shown as following
When the difference between the setting temperature and the room temperature equal to 2
℃
or
4
℃
, the indoor fan speed will keep in current speed.
3-7-3 Air flow direction control
The horizontal louver is controlled by a step motor, press the SWING button to swing or stop the
louver.
During the louver run in normal operation, the current position will be stored. When the
appliance turn off and louver swing automatically to the default position, it will position at the default
position plus 5º.
4-3-8-4 Outdoor fan
The outdoor fan speeds except single speed motor can be changed according to outdoor ambient