DC INVERTER AIR CONDITIONER TECHNICAL& SERVICE MANUAL V5.0
22
Model
AUV-18UR4SZA1
AUV-24UR4SAA1
AUV-36UR4SAB1
AUV-48UR6SPC
AUV-60UR6SPC
Winding
resistance
(at20
℃
)
M:187A:245,60,33,143
M:209.4;A:245,60,33,143
M:75;A:97.5
M:79.7;A:59.4,20.2,108
M:79.7;A:59.4,20.2,10
8
Outdoor
Model
ARW4401QH
SIC-71FW-D8121-1
SIC-71FW-D8121-1
YDK65-6-9024
YDK65-6-9024
YDK65-6-9061
YDK65-6-9061
Winding
resistance
(at20
℃
)
M:231.5;A:168
M:78;A:36.2,51.5,109.2
M:59.1;A:85.8
M:83;A1:23.4A2:14A1:6
3.5
M:83;A1:23.4A2:14A1:
63.5
Fan Indoor
type
centrifugal fan
Speed
Hi/Med/Low
r.p.m
630/720/850
910/1030/1150
1080/1160/1220
1000/1100/1200
1000/1100/1200
Fan speed
Outdoor
type r.p.m
tube-axial
Speed
Hi/Med/Low
r.p.m
0-810
0-810
0-810
500/600/700
500/600/700
Air circulation
Indoor Hi/Med/Low
m³/h
800
1100
1600
2000
2000
Outdoor Hi/Med/Low
m³/h
--
--
--
--
--
Static Pressure(*Default Setting)
Pa
0
0
0
0
0
Operating control
Wireless Remote control-J1-05(E)
Dimensions
Indoor L×W×H
mm
990×680×230
990×680×230
1290×680×230
1580×680×230
1580×680×230
Outdoor L×W×H
mm
900×300×640
950×340×840
950×340×840
950×340×1386
950×340×1386
Packing
Indoor L×W×H
mm
1100×820×350
1100×820×350
1400×820×350
1690×820×350
1690×820×350
Outdoor L×W×H
mm
1050×700×400
1110×460×980
1110×460×980
1110×460×1530
1110×460×1530
Weight
Indoor Net/Gross
kg
27/33
30/35
37/44
47/54
47/54
Outdoor Net/Gross
kg
45/51
69/73
70/74
101/107
108/112
Noise lever
Indoor Hi/Med/Low
dB(A)
--/54(SOUND POWER)
--/63(SOUND POWER)
--/64(SOUND
POWER)
48/50/53
48/50/53
Outdoor Hi/Med/Low
dB(A)
--/62(SOUND POWER)
-
-/66(
SOUND POWER)
--/70(SOUND
--/60
--/60