15.Troubleshooting
Troubleshooting according to fault codes
When the air conditioner failure occurs, the fault code will be displayed on the control board, wired
remote controller or display panel
.
How to check fault codes
Indoor Unit
1. Continue pressing “SLEEP” button of wireless remote controller for 4 times, fault codes will
display on the LCD for 10 seconds, and automatically disappears after 10 seconds.
2. Display on the panel.
15. TROUBLESHOOTING
15.1 Trouble guide
Troubleshooting for Normal Malfunction
Troubleshooting
Possible Reason of Abnormality
How to Deal With
Air conditioner can not start up
1.
Power supply failure;
2.
Trip of breaker or blow of fuse
;
3.
Power voltage is too low;
4. Improper s
etting of remote
controller;
5.
Remote controller is short of
power.
1. Check power supply circuit;
2. Measure insulation resistance to
ground to see if there is any
leakage;
3. Check if there is a defective
contact or leak current in the
power supply circuit;
4. Check and set remote
controller again;
5. Replace batteries.
The compressor starts or
stops frequently
The air inlet and outlet has been
blocked.
Remove block obstacles.
Poor cooling/heating
1.
2.
3.
The outdoor heat exchanger is
dirty, such as condenser;
There are heating devices indoors
;
The air tightness is not enough, and
people come in and out too
frequently.
4.
Block of outdoor heat exchanger;
5.
Improper set
ting
of temperature.
1. Clean the heat exchanger of the
outdoor unit, such as condenser ;
2. Remove heating devices;
3. Keep certain air tightness indoors;
4. Remove block obstacles;
5. Check and try to set temperature
again.
Sound from deforming parts
During system starting or stopping, a
sound might be heard. However, this
is due to thermal deformation of
plastic parts.
It is not abnormal, and the sound will
disappear soon.
Water leakage
1.
Drainage pipe blocked or broken;
2.
Wrap of refrigerant pipe joint is not
close
d
completely
.
1. Change the drainage pipe;
2. Re-wrap and make it tight.