Symbol
Value
Unit
Item
Symbol
Value
Unit
P
rated
,
c
22.4
kW
Seasonal space cooling
energy efficiency
η
s,c
239
%
Outdoor
temperature Tj
water loop inlet /
outlet temperature
Tj=+35
℃
30/35
P
dc
22.4
kW
Tj=+35
℃
EER
d
5.82
—
Tj=+30
℃
26/*
P
dc
16.6
kW
Tj=+30
℃
EER
d
11.0378
—
Tj=+25
℃
22/*
P
dc
10.5
kW
Tj=+25
℃
EER
d
15.3297
—
Tj=+20
℃
18/*
P
dc
4.7
kW
Tj=+20
℃
EER
d
10.0649
—
C
dc
0.25
—
P
OFF
0.048
kW
Crankcase heater mode
P
CX
0.048
kW
P
TO
0.048
kW
Standby mode
P
SB
0.048
kW
Symbol
Value
Unit
Item
Symbol
Value
Unit
P
rated
,
h
25
kW
Seasonal space cooling
energy efficiency
η
s,h
223
%
Outdoor
temperature Tj
water loop inlet /
outlet temperature
Tj=-7
℃
10/*
P
dh
15.4
kW
Tj=-7
℃
COP
d
5.57
—
Tj=+2
℃
10/*
P
dh
9.5
kW
Tj=+2
℃
COP
d
6.24
—
Tj=+7
℃
10/*
P
dh
6.1
kW
Tj=+7
℃
COP
d
6.17
—
Tj=+12
℃
10/*
P
dh
2.6
kW
Tj=+12
℃
COP
d
3.92
—
P
dh
15.4
kW
Tj=bivalent temperature
COP
d
5.57
—
P
dh
17.5
kW
Tj=operating limit
COP
d
5.21
—
T
biv
-7
℃
heating/Average
T
ol
-10
℃
T
biv
—
℃
heating/Wamer
T
ol
—
℃
T
biv
—
℃
heating/Colder
T
ol
—
℃
C
dc
0.25
P
OFF
0.048
kW
Back-up heating capacity (*)
elbu
0
kW
P
TO
0.048
kW
Type of energy input
P
CK
0.048
kW
standby mode
P
SB
0.048
kW
Rated water flow rate
—
4.6
m3/h
LWA
49/51
dB(A)
GWP
2088
kg CO2 eq.
(100 years)
Driver of compressor: electric motor
Technical Parameters
Model(s): AVWW-76FKFW
Outdoor side heat exchanger of air conditioner/heat pump: water
Indoor side heat exchanger of air conditioner/heat pump: air
Type: compressor driven vapour compression
thermostat-off mode (heating)
crankcase heater mode
Item
Indication if the heater is equipped with a supplementary heater: no
Parameters shall be declared for the average heating season
Cooling
Item
Rated cooling capacity
Declared cooling capacity (*) for part loadat given outdoor temperatures Tj and
indoor 27(19)
℃
Declared energy efficiency ratio (*) for part load at given
outdoor temperatures Tj
Degradation co-efficient for air
conditioners (**)
Power consumption in modes other than 'active mode'
Off mode
Thermostat-off mode
Heating
off mode
Rated cooling capacity
Declared capacity (*) for cooling, at indoor temperature 20
℃
and
outdoor temperature Tj
Declared coefficiency of performance (*) /Average season, at
indoor temperature 20
℃
and outdoor temperature Tj
Tj=bivalent temperature
Tj=operating limit
Bivalent temperature
Operating limit temperature
heating/Average
heating/Wamer
heating/Colder
Degradation co-efficient heat pumps (**
)
Power consumption in modes other than ’active mode'
Contact details
Qingdao Hisense Hitachi Air-conditioning Systems Co., Ltd.
218,Qianwangang Road, Economic and Technological Development Zone, Qingdao, P.R. China
Other items
capacity control
variable
Global warming potential
Note
The above performance data is obtained on the basis of the performance of this outdoor unit,
with a 100%-combination of ceiling ducted type indoor units.
Sound power level, indoor/outdoor
measured