background image

11

1

0

A

  

0

7

14

18

2

4

Drain Pipe Connection

Liquid Pipe Connection

Gas Pipe Connection

 Flaring Dimension

       Perform the flaring work as shown below.  

Pipe 

Diameter (a)

Flaring

 

Diameter

 (D)

12.7mm

60

(PVC, VP25)

Summary of Contents for AVY-07UXJSJA

Page 1: ...AVY 24UXJSKA AVY 18UXJSKA AVY 14UXJSJA AVY 12UXJSJA AVY 09UXJSJA AVY 07UXJSJA P01135Q ORIGINAL INSTRUCTIONS 1 Way Cassette Type...

Page 2: ......

Page 3: ...30 EU 2012 19 EU 2011 65 EU Directives as amended Manufacturing number and manufacturing year refer to model Nameplate Notes This declaration becomes invalid if technical or operational modifications...

Page 4: ...Hisense Hisense Hisense...

Page 5: ...s To prevent possible harm to the environment or human health from uncontrolled waste disposal recycle it responsibly to promote the sustainable reuse of material resources To return your used device...

Page 6: ...6 6 6 6 7 6 6 6 9 8 7 11 11 11 12 Section2 Installation Maintenance Manual...

Page 7: ...13 13 13 14 15 15 15 16...

Page 8: ...sical sensory or mental capabilities or lack of experience and knowledge unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety...

Page 9: ...indi tion is 30 c Set and Actual Temperature The set temperatu is fo the air temperatu at the sensor thermistor of the ind r unit The actual room temperature may be di erent 2 from the ai tempe ture...

Page 10: ...Regarding the instructions of Wired Remote Control Switch or Wireless Remote Control Switch read the operation manual attached to the control switch...

Page 11: ...7 7 1 outlet Outlet Knob Right Side Left Side Note There are two grilles on the panel of HP E NA which should be removed respectively...

Page 12: ...8 2 8 4 8 7 2 7 3 Left Side Knobs two Zoom in View of Knob Right side Remove the other filter screen in the same way 8 3...

Page 13: ...6 R410A To avoid damage to the resin covers before lifting or moving the indoor unit put a cloth on the resin covers 21 Wrench...

Page 14: ...7 2 3 Indoor Unit Panel Selected 07 14 HP D NA 18 24 HP E NA Air Panel optional 8 Screw 8 Magnet Ring 1 For Fixing Magnet Ring 1...

Page 15: ...50mm Min 150mm Min 1500mm Min 500mm Min Piping Connection Distance From Wall Side 1 500mm Min 150mm Min 150mm Min 500mm Min Piping Connection Side 1 000mm Min Service Space 230mm Min Service Hole 450M...

Page 16: ...nsert 100 to150kg Concrete Anchor Bolt W3 8 or M10 For Steel Beam Suspension Bolt W3 8 or M10 l Beam For Wooden Beam Wooden Rib 60 to 90mm square timber Wooden Beam Suspension Bolt Square Washer Nut N...

Page 17: ...checking scale provided by the factory Dimension of Opening Connected to Indoor Unit Indoor Unit Ceiling Supported by Surface of Ceiling Fig 4 7 Adjustment of Distance to Indoor Unit 3 Cutting the Ce...

Page 18: ...11 10A 07 14 18 24 Drain Pipe Connection Liquid Pipe Connection Gas Pipe Connection Flaring Dimension Perform the flaring work as shown below Pipe Diameter a Flaring Diameter D 12 7mm 60 PVC VP25...

Page 19: ...he drain pipe and hose clamp provided by the manufacture b Do not impose too much force on the pipe joint to prevent damage to it c Do not use any bent or twisted pipe which may cause leakage d Comple...

Page 20: ...ric shock or fire may be caused Wire shall be fixed securely since external force imposed to the connecting terminal may make it loose and thereby cause fire Do not use the power terminal strip used f...

Page 21: ...ctrical box and take care not to press any wire After wire is connected to terminal board be sure to fix it with cord clamp and lay the wire in cable tray to prevent it from being squeezed and fire ca...

Page 22: ...VV F and Completely seal the end of conduit tube with sealing materials Run through the cables using conduit tube Use an ELB Electric Leakage Breaker If not used it will cause an electric shock or a f...

Page 23: ...h 3 Capacity 10 Btu h 3 H LINK II H LINK II H LINK II H LINK II 5 0 ON OFF DSW4 Unit Mode Code Setting DSW3 Capacity Code Setting DSW6 Unit No Setting RSW1 Unit No Setting DSW7 Fuse Recover RSW2 Refri...

Page 24: ...18 03 V02 1084931 Qingdao Hisense Hitachi Air conditioning Systems Co Ltd Add 218 Qianwangang Road Economic Technical Development Zone Qingdao P R China http www hisense vrf com E mail export hisenseh...