Air

 

conditioner will not operate

 

 

 

The

 

power

 

supply

 

cord

 

is

 

unplugged

Plug into

 

grounded

 

 

3

prong

 

outlet

See

 "

Electrical

 

Requirements”

.

The

 

power

 

supply

 

cord

 

has

 

tripped

 (

Reset

 

button

 

has

 

popped

 

out

). 

Press and release

 

RESET

 (

listen

 

for

 

click

Reset

 

 

 

button

 

will

 

latch

 

and

 

on

 

some

 

devices

a

 

green

 

light

 

will

 

turn

 

on

)

to

 

resume

 

operation

.

 

A household fuse

 

has blown or

 

circuit

 

breaker

 

has

 

 

 

 

tripped

Replace

 

the

 

fuse

 

or

 

reset

 

the

 

circuit

 

breaker

If

 

the

 

problem continues

call

 

an

 

electrician

See

 "

Electrical

 

 

Requirements”

.

The

 

Power button

 

has

 

not

 

been

 

pressed

 

Press

 

the

 

Power

 

button

.

The

 

local

 

power has

 

failed

.

 

 

Wait

 

for

 

power

 

to

 

be

 

restored

.

Air

 

conditioner

 

blows

 

fuses

 

or

 

trips

 

circuit

 

breakers

Too

 

many

 

appliances

 

are

 

being

 

used

 

on

 

the

 

same

 

circuit

Unplug

 

or

 

relocate

 

appliances

 

that

 

share

 

the

 

same

 

circuit

.

Time delay fuse or

 

circuit

 

breaker

 

of

 

the

 

wrong

 

capacity

 

-

 

 

is being

 

used

 

Replace

 

with

 

a

 

time

-

delay

 

fuse

 

or

 

circuit

 

breaker

 

of

 

the

 

correct

 

capacity

See

 "

Electrical

 

Requirements”

.

An extension

 

cord

 

is

 

being

 

used

.

 

 

 

Do not

 

use

 

an

 

extension

 

cord

 

with

 

this

 

or any

 

other

 

appliance

.

 

You

 

are

 

trying

 

to

 

restart

 

the

 

air

 

conditioner

 

too

 

soon

 

after

 

turning

 

off

 

the air conditioner

 

 

Wait

 

at

 

least

 

minutes

 

after

 

 3

turning

 

off

 

the

 

air

 

conditioner

 

before

 

trying

 

to

 

restart

 

the

 

air

 

conditioner

.

Air conditioner

 

power

 

supply

 

cord

 

trips

 

Reset

 

button

 

 

(

pops

 

out

)

Disturbances

 

in

 

your

 

electrical

 

current

 

can

 

trip

 (

Reset

button

 

will

 

pop

 

out

the

 

power

 

supply

 

cord

.

release

 

RESET

 (

listen

 

for

 

click

Reset

 

button

 

will

 

latch

 

and

 

on

 

some

 

devices

a

 

green

 

light

 

will

 

turn

 

on

to

 

resume

 

operation

.

Electrical

 

overloading

overheating

,

cord

 

pinching

 

or

 

 

aging

 

can

 

trip

 (

Reset

 

button

 

will

 

pop

 

out

the

 

power

 

supply

 

cord

.

RESET

 (

listen

 

for

 

click

Reset

 

button

 

will

 

latch

 

and

 

on

 

some

 

devices

a

 

green

 

light

 

will

 

turn

 

on

to

 

resume

 

operation

.

NOTE

:   

A damaged

 

power

 

supply

 

cord

 

must

 

be

 

replaced

 

with

 

a

 

new power

 

supply

 

cord

 

obtained

 

from

 

the

 

product

 

manufacturer

 

 

and

 

must

 

not

 

be

 

repaired

.

Air

 

conditioner

 

seems

 

to

 

run

 

too

 

much

The

 

current

 

air

 

conditioner

 

replaced

 

an

 

older

 

model

The

 

use of more

 

efficient components

 

may

 

cause

 

the

 

air

 

   

 

conditioner

 

to

 

run

 

longer

 

than

 

an

 

older

 

model

but

 

the

 

total

 

energy

 

consumption

 

will

 

be

 

less

Newer

 

air

 

conditioners

 

do

 

not emit

 

the

 "

blast”

 

of

 

cold

 

air

 

you

 

may

 

be

 

accustomed

 

to

 

 

from

 

older

 

air

 

conditioners

but

 

this

 

is

 

not

 

an

 

indication

 

of

 

lesser

 

cooling

 

capacity

 

or

 

efficiency

Refer

 

to

 

the

 

efficiency

 

rating

 (

EER

and

 

capacity

 

rating

 (

in

 

Btu

/

h

marked

 

on

 

the

 

air

 

conditioner

.

The

 

air

 

conditioner

 

is

 

in

 

a

 

heavily

 

occupied

 

room

or

 

heat

-

producing

 

appliances

 

are

 

in

 

use

 

in

 

the

 

room

Use

 

exhaust

 

vent fans

 

while

 

cooking

 

or

 

bathing

 

and

 

try

 

not

 

to

 

use

 

heat

-

 

producing

 

appliances

 

during

 

the

 

hottest

 

part

 

of

 

the

 

day

A

 

higher

 

capacity

 

air

 

conditioner

 

may

 

be

 

required

depending

 

on

 

the size of the room

 

being

 

cooled

.

 

   

 

Air conditioner

 

cycles

 

on

 

and

 

off

 

too

 

much

 

or

 

does

 

not

 

 

cool

The

 

air

 

conditioner

 

is

 

not

 

properly

 

sized

 

for

 

your

 

room

Check

 

the

 

cooling

 

capabilities

 

of

 

your

 

room

 

air

 

conditioner

Room air

 

conditioners are

 

not

 

designed

 

to

 

cool

 

multiple

 

 

 

rooms

The

 

filter

 

is

 

dirty

 

or

 

obstructed

 

by

 

debris

Clean

 

the

 

filter

The

 

inside evaporator and outside

 

condenser

 

coils

 

are

 

 

 

 

dirty

 

or

 

obstructed

 

by

 

debris

See

 

Annual

 

Maintenance

.

There

 

is

 

excessive

 

heat

 

or moisture

 (

open

 

container

 

cooking

showers

etc

.) 

in the

 

room

.

 

 

Use

 

a

 

fan

 

to

 

exhaust

 

heat

 

or moisture from

 

the

 

room

Try

 

not

 

to

 

use

 

heat

-

 

 

producing

 

appliances

 

during

 

the

 

hottest

 

part

 

of

 

the

 

day

.

The

 

louvers are

 

blocked

.

 

 

Install

 

the

 

air

 

conditioner

 

in

 

a

 

location

 

where

 

the

 

louvers

 

are

 

free

 

from

 

curtains

blinds

furniture

etc

.

Electrical Shock Hazard

 

 

Plug into a grounded

prong outlet

 

   

 3 

 

.

Do not remove ground prong

 

 

 

 

.

Do not use an adapter

 

 

 

 

.

Do not use an extension cord

 

 

 

 

 

.

Failure to follow these instructions can result in death

   

 

 

 

 

   

fire or electrical shock

,   

 

.

WARNING

After

 

correcting

 

the

 

problem

press

 

and

 

release

Press

 

and

Summary of Contents for AW0521CK1W

Page 1: ...Model AW0521CK1W ...

Page 2: ...ents INSTALLATION INSTRUCTIONS Unpack the Air Conditioner Prepare Air Conditioner for Installation Window Air Conditioner Installation Complete Installation Starting Your Air Conditioner AIR CONDITIONER USE Changing Air Direction Normal Sounds AIR CONDITIONER CARE 10 10 Cleaning the Front Panel 10 Repairing Paint Damage 10 TROUBLESHOOTING 11 9 Cleaning the Air Filter 10 ...

Page 3: ... or sideways to avoid damage to the compressor The wiring diagram is shown at nameplate on the air conditioner This appliance is not intended for use by persons including children with reduced physical sensory or mental capabilities or lack of experience and knowledge unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety Chi...

Page 4: ...ce may differ from the one shown T o test your power supply cord 1 Plug power supply cord into a grounded 3 prong outlet 2 Press RESET on some devices a green light will turn on 3 Press TEST listen for click Reset button will trip and on some devices a green light will turn off 4 Press and release RESET listen for click Reset button will latch and on some devices a green light will turn on The pow...

Page 5: ...Remove packaging materials Remove and dispose of recycle packaging materials Remove tape and glue residue from surfaces before turning on the air conditioner Rub a small amount of liquid dish soap over the adhesive with your fingers Wipe with warm water and dry Unpack the Air Conditioner Do not use sharp instruments rubbing alcohol flammable fluids or abrasive cleaners to remove tape or glue These...

Page 6: ...ed without the side curtain panels if needed to fit in a narrow window See the window opening dimensions All supporting parts must be secured to firm wood masonry or metal The electrical outlet must be within reach of the power cord Follow the dimensions in the table and illustration for your model A With side curtain panels B Models A B 5K BTU 12 2 315mm min 5 22 37 4 5 559mm 960mm Read these ins...

Page 7: ...nditioner A B Attach Top Rail 1 Locate the bag of screws provided 2 Place the top rail on top of the air conditioner cabinet lining up the 4 holes in the top rail with the 4 holes on top of the air conditioner cabinet 3 Using four 10mm screws attach the top rail to the air conditioner cabinet A Curtain housing A Side curtain B Curtain top rail B Air conditioner cabinet B A 3 8 A B Top rail 3 screw...

Page 8: ...our model may differ from the one shown Window Air Conditioner Installation 2 Use a drill bit to drill a starter hole through the 3mm hole in the top rail 1 8 Attach Side Curtains to Window 1 Pull the left hand curtain out until it fits into the window channel 3 Insert one of the 3 4 9mm 1 screws through the left hand curtain and into the window sash A Window sash B Hole in side curtain C 3 4 scre...

Page 9: ...o not use an adapter Do not use an extension cord Failure to follow these instructions can result in death fire or electrical shock WARNING AIR CONDITIONER USE Operating your air conditioner properly helps you to obtain the best possible results This section explains proper air conditioner operation IMPORTANT If you turn off the air conditioner wait at least minutes 3 before turning it back on Thi...

Page 10: ...ature Rotate the thermostat selector counter clockwise for lower cool settings Lower cool settings will provide higher room temperature To set the desired room temperature rotate the thermostat switch to the desired setting After the set temperature is achieved the thermostat will automatically start and stop the compressor in order to maintain the desired set temperature Fan Speed Fan Only NOTE N...

Page 11: ...r in place 1 Turn off the air conditioner 3 Use a vacuum cleaner to clean the air filter If the air filter is very dirty wash it in warm water with a mild detergent Do not wash the air filter in the dishwasher or use any chemical cleaners Air dry the filter completely before replacing to ensure maximum efficiency 4 Replace the air filter back into the air conditioner and colse the front panel Clea...

Page 12: ... green light will turn on to resume operation NOTE A damaged power supply cord must be replaced with a new power supply cord obtained from the product manufacturer and must not be repaired Air conditioner seems to run too much The current air conditioner replaced an older model The use of more efficient components may cause the air conditioner to run longer than an older model but the total energy...

Page 13: ...o a cooler setting by pressing the minus button to reduce the temperature Set the Fan Speed control to the highest setting Water drips from cabinet into your house The air conditioner is not properly leveled The air conditioner should slope slightly downward toward the outside Level the air conditioner to provide a downward slope toward the outside to ensure proper drainage See the Installation In...

Page 14: ...4179381 02 ...

Reviews: