background image

4

Tools

 

and

 

Parts

Gather

 

the

 

required

 

tools

 

and

 

parts

 

before

 

starting

 

installation

Read

 

and

 

follow

 

the

 

instructions

 

provided

 

with

 

any

 

tools

 

listed

 

here

.

Tools

 

needed

Parts supplied

 

Check

 

that

 

all

 

parts

 

are

 

included

 

in

 

parts

 

package

.

Phillips

 

screwdriver

Scissors

Level

Tape

 

measure

Cordless

 

drill

 

and 

 

 

bit

Pencil

A Adhesive

 

seal (2)

 

.

B Foam

 

seal

.

C

.  

lock

 

frame

(

for

 

Wooden

 

windows

)(2) 

I

.  

sash lock

 

J

.  

EVA foam(2)

 

L

.

 Remote control 

 

D

.  

lock

 

frame

(

for

 

Vinyl-Clad

 

windows

)(2) 

G Side

 

curtains

 (2)

.

A

B

C

I

J

D

K

L

H Top rail

.

H

E F

G

NOTE

The

 

                       

 

     is not provide for

10K\12K 

cooling only

 

The J. EVA foam(2) is not provide for 

6K regular

 cooling only

 

H

.

Top rail

     1

 

/8"

     E. 3

 screws(4)

 

/8"

     E. 3

 screws(4)

 

/8"

     F. 

 screws(7)

 

3/4"

     K. Air conditioner 

Packaging

(

8K BTU Model

Top Rail

(

6K BTU Model

Top Rail

Remove

 

packaging

 

materials

Remove

 

and

 

dispose

 

of

/

recycle

 

packaging

 

materials

Remove

 

tape and

 

glue residue

 

from

 

surfaces

 

before

 

turning

 

 

 

on

 

the

 

air

 

conditioner

Rub

 

a

 

small

 

amount

 

of

 

liquid

 

dish

 

soap

 

over

 

the

 

adhesive

 

with

 

your

 

fingers

Wipe

 

with

 

warm

 

water

 

and

 

dry

.

Unpack

 

the

 

Air

 

Conditioner

Do

 

not

 

use

 

sharp

 

instruments

rubbing

 

alcohol

flammable

 

fluids

or

 

abrasive

 

cleaners

 

to

 

remove

 

tape

 

or

 

glue

These

 

products

 

can

 

damage

 

the

 

surface

 

of

 

your

 

air

 

conditioner

Handle

 

the

 

air

 

conditioner

 

gently

.

WARNING

Excessive Weight Hazard

 

 

Use two or more people to move and install

 

   

 

   

 

 

 

air conditioner

 

.

Failure to do so can result in back or other injury

   

   

 

   

   

 

.

Remove top rail from the packaging material

.

M

M

.

S

ealing sponge

The M.Sealing sponge is provide for 
6K DOE cooling only

 

Summary of Contents for AW0621CR1W

Page 1: ...Model AW0621CR1W AW1221CW1W AW1021CW1W AW0821CW1W ...

Page 2: ...INSTRUCTIONS Unpack the Air Conditioner Prepare Air Conditioner for Installation Window Air Conditioner Installation Complete Installation Starting Your Air Conditioner AIR CONDITIONER USE Using the Remote Control Changing Air Direction Exhaust Air Vent Normal Sounds AIR CONDITIONER CARE 13 13 Cleaning the Front Panel 13 Repairing Paint Damage 13 TROUBLESHOOTING 14 9 Cleaning the Air Filter 13 ...

Page 3: ... or sideways to avoid damage to the compressor The wiring diagram is shown at nameplate on the air conditioner This appliance is not intended for use by persons including children with reduced physical sensory or mental capabilities or lack of experience and knowledge unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety Chi...

Page 4: ...circuit breaker for 10K 12K cooling only NOTE Your air conditioner s device may differ from the one shown T o test your power supply cord 1 Plug power supply cord into a grounded 3 prong outlet 2 Press RESET on some devices a green light will turn on 3 Press TEST listen for click Reset button will trip and on some devices a green light will turn off 4 Press and release RESET listen for click Reset...

Page 5: ... screws 4 8 F screws 7 3 4 K Air conditioner Packaging 8K BTU Model Top Rail 6K BTU Model Top Rail Remove packaging materials Remove and dispose of recycle packaging materials Remove tape and glue residue from surfaces before turning on the air conditioner Rub a small amount of liquid dish soap over the adhesive with your fingers Wipe with warm water and dry Unpack the Air Conditioner Do not use s...

Page 6: ...f needed to fit in a narrow window See the window opening dimensions All supporting parts must be secured to firm wood masonry or metal The electrical outlet must be within reach of the power cord Follow the dimensions in the table and illustration for your model A With side curtain panels B Models A B 6K BTU 6K E star 8K BTU 10K BTU 12K BTU 12 2 315mm min 5 15 1 min 5 386mm 13 3 345mm min 5 22 55...

Page 7: ...e top rail to the air conditioner cabinet A Curtain housing A Side curtain B Curtain top rail B Air conditioner cabinet A B NOTE The top rail had attached by manufacturer Models 10K 12K cooling only 3 8 A B Top rail 3 screws 8 Window Air Conditioner Installation WARNING Excessive Weight Hazard Use two or more people to move and install air conditioner Failure to do so can result in back or other i...

Page 8: ...l 1 8 Attach Side Curtains to Window 1 Pull the left hand curtain out until it fits into the window channel 3 Insert one of the 3 4 9mm 1 screws through the left hand curtain and into the window sash A Window sash B Hole in side curtain C 3 4 screw A B C 4 Put one EVA Foam on the Curtain housing In order to minimize air leaks and ensure optimal insulation it is necessary to install the EVA Foam on...

Page 9: ...ditioner operation IMPORTANT If you turn off the air conditioner wait at least minutes 3 before turning it back on This prevents the air conditioner from blowing a fuse or tripping a circuit breaker NOTE In the event of a power failure your air conditioner will operate at the previous settings when the power is restored A operation the better limits Outdoor side 64 4 109 4 F 18 43 C 80 RH indoor s...

Page 10: ... High Low Med High FAN FAN Low Med High Low Med High Dry Fan Cool Eco Dry Fan Cool Eco MODE MODE Dry Fan Cool Eco Dry Fan Cool Eco MODE CONNECT CONNECT NOTE NOTE Dry mode should not be used to cool the room Select ECO mode to initiate this function The fan will continue to run after the compressor shuts off for 2 minutes 4 minutes for the first time so the fan will shuts off for 10 minutes The fan...

Page 11: ...er WIFI WIFI control is available for connected models with this logo on control panel CONNECT CONNECT 1 Press the CONNECT button for 5s the LED start to falsh 2 After the WIFI module connecting the router the LED keeps on Or the LED keeps off Timer Sleep Filter Timer Sleep Filter NOTE is available for models WIFI control WIFI control ...

Page 12: ...ndicator on the bracket A A Bracket When the first use please remove the insulated plastic patch after 6 months of use or when the 5 T o turn off Sleep control press SLEEP again or wait 8 hours for the air conditioner to turn off automatically NOTE The air conditioner will return to previous settings after Sleep control is turned off T emperature DIMMER Press the DIMMER button to turn off the cont...

Page 13: ...n Use the Vertical Level Vane to direct the air right or left Use the whole cartridge to direct air up down or straight ahead A Vertical Level Vane B Cartridge A B Exhaust Air Vent Pull out the exhaust air vent control to Open the exhaust air vent and draw stale or smoky air from the room Push in the exhaust air vent control to close the exhaust air vent for maximum continuous cooling NOTE NOTE Th...

Page 14: ...t 3 Use a vacuum cleaner to clean the air filter If the air filter is very dirty wash it in warm water with a mild detergent Do not wash the air filter in the dishwasher or use any chemical cleaners Air dry the filter completely before replacing to ensure maximum efficiency 4 Replace the air filter back into the air conditioner and colse the front panel Cleaning the Front Panel 1 Turn off the air ...

Page 15: ... green light will turn on to resume operation NOTE A damaged power supply cord must be replaced with a new power supply cord obtained from the product manufacturer and must not be repaired Air conditioner seems to run too much The current air conditioner replaced an older model The use of more efficient components may cause the air conditioner to run longer than an older model but the total energy...

Page 16: ...o a cooler setting by pressing the minus button to reduce the temperature Set the Fan Speed control to the highest setting Water drips from cabinet into your house The air conditioner is not properly leveled The air conditioner should slope slightly downward toward the outside Level the air conditioner to provide a downward slope toward the outside to ensure proper drainage See the Installation In...

Page 17: ......