4.3 Defrost mode
4.Operation and functions
4.3.1 Start condition
When
compressor
accumulated
running
time
reach the
setting
point
(depends
on
the
environment
temperature)
,
it
will
enter defrost
mode
automatically.
4.3.2 Defrost flow
Compressor stops
Evaporator fan stops
Damper stops
Defrost heater works
Evaporator temperature reach the
setting point,exit defrost mode
Defrost heater stops
Compressor starts
several minutes delay
Evaporator fan starts
several minutes delay
Damper starts
Start
17