Hints:
When the alarm signal switch is activated
the telephone will call up according to the chosen delay
time.
To do so, there must be a telephone number programmed and a telephone line connected.
When the telephone starts calling, the alarm signal bell ceases and the connection sound is clearly
heard in the speaker unit.
Adjust the volume with the volume control in the Main unit.
The first two telephone numbers
(primary and secondary) are pre-programmed for P100. There
must be an 8-figure alarm code programmed to make the P100/CPC alarm work. The last two
telephone numbers (third and forth) are programmed for vocal connection. Vocal connection means
a standard telephone call.
The receiving party does not have to do anything to get a vocal connection it is automatically done.
To disconnect a vocal connection
the receiving party should press "9" or "#" otherwise the line will
be busy about 90 seconds after completion of the call.
To call the lift telephone
just call the connecting telephone number. The telephone will after 2
signals automatically connect the call.
Disconnect after completion of the call by pressing "9" or "#".
To call the lift telephone, if they are connected in series
The telephones must be programmed with different unit numbers (see programming). When calling
to the lift telephone it will answer after 2 signals, chose the unit number that corresponds to the
telephone you want to call.
Ex: You want to talk to unit number 3.
Call the telephone number and, when the telephone answers, press "3" repeatedly on your
dialtone telephone or mobile telephone, until you hear 2 distinctive calling tones the call is then
connected to the right telephone.
Disconnect after completion of the call by pressing "9" or "#".
One of the 4 programmed telephone numbers could be to a beeper.
The telephone can be programmed to leave a digital code to the beeper.
To make it work the alarm type must be changed to "MINICALL".
If it does not work, check:
Is there a connection? -The diode lamp "LINE" should not be red.
Is there power? -The diode lamp ”POWER” should glow/blink red or green.
Is remote unit connected right? - Check the connection (Note the crossed connections!).
If you connect it via modular plugs - Check that incoming line is connected on the 2 inner pins.
Is there any telephone number programmed? - Check with the hand unit.
Is there any alarm code programmed? - Check with the hand unit.
Is it calling the right number? - Check by calling on a regular phone.