English
22
MAINTENANCE
NOTE:
The information contained in this Manual is designed to assist you in the safe
maintenance of the Nailer.
Some illustrations in this Manual may show details or attachments that differ
from those on your own Nailer.
MAINTENANCE AND INSPECTION
Read section titled “SAFETY” (pages 4 – 7).
●
Disconnect air hose and remove all nails from Nailer when:
1)
doing maintenance and inspection; and
2)
clearing a jam.
1. Clearing a jam
Remove a jammed nail in the following
order:
1
DISCONNECT AIR HOSE.
2
Remove all nails.
3
Release the lock lever and open
guide plate.
4
Remove the jammed nail with a
slotted-head screwdriver.
5
Close guide plate and latch.
6
In case of frequent jam, contact a
Hitachi authorized service center.
2. Maintenance chart (See page 24)
3. Operator troubleshooting (See page 25)
4. Storing
䡬
When not in use for an extended period, apply a thin coat of the lubricant to the steel
parts to avoid rust.
䡬
Do not store the Nailer in a cold weather environment.
Keep the Nailer in a warm area.
䡬
When not in use, the Nailer should be stored in a warm and dry place.
Keep out of reach children.
WARNING
Disconnect
air hose
Guide Plate (A)
Lock lever
1
3