- 24 -
To Check Purity:
Press the Recall Button on the Remote Control when in Serviceman Mode (red “CHK” is displayed) to enter the
Purity Field Check Mode.
Press Recall again to select desired field.
NORMAL
SCREEN
WHITE
SCREEN
RED
SCREEN
GRN.
SCREEN
BLUE
SCREEN
Figure 14. Purity Check Field Mode.
Helpful Hints
Entering Serviceman Mode (Back-Open Method)
1.
While the Receiver is ON and operating in Normal Mode, momentarily
short test point FA1 (TP8) to Cold Ground (
) FA2 (TP3) A-Board.
The Receiver enters the Aging Mode
.
Yellow letters “CHK” appear in the upper left corner of the CRT.
(The Volume Up/Down will adjust rapidly).
2.
Simultaneously press the Menu and the Volume Up buttons on the
Receiver Control Panel.
The Receiver enters the Serviceman Mode.
The letter in “CHK” turn red.
(The Volume Up/Down will adjust normally).
(All customer controls are set to nominal level).
IMPORTANT NOTE:
Always Exit the Serviceman
Mode Following Adjustments.
Summary of Contents for 27GX01B-501