3–20
Maintenance log and tracing functions
Hitachi AMS 2000 Family Command Control Interface (CCI) Reference Guide
9576
x08D
94
The S-VOL of the remote array
does not meet the conditions of
cascading with a SnapShot pair.
Check the LU status of the LU
in the remote array.
9576
x090
94
The S-VOL of the remote array
does not meet the conditions of
cascading with a SnapShot pair.
Check the LU status of the LU
in the remote array.
9576
x091
94
The indicated Array ID is not same
as the actual one for remote array.
Confirm the Array ID for the
remote array.
9576
x095
94
The S-VOL in the remote array is
undergoing the forced parity
correction.
Check the status of the
remote array and retry after
waiting for a while.
9576
x097
94
The S-VOL in the remote array
received an illegal command.
Check the status of the
remote array.
9576
x09A
94
The LU status of the S-VOL in the
remote array is normal or other
than regressed.
Check the LU status of the
remote array.
9576
x09F
94
The internal transaction which are
splitting or deleting for SnapShot
is working now.
Retry after waiting for a
while.
9576
x0A0
94
The remote array has no pool LU. Make a pool LU for the
remote array.
9576
x0A1
94
The LU specified as the S-VOL in
the remote array is a pool LU.
The pool LU cannot be set to
an S-VOL. Check the pool LU
status of the remote array.
9576
x0A2
94
The LU status of the S-VOL in the
remote array is normal or other
than regressed.
Check the pool LU status of
the remote array.
9576
x0A3
94
The pool LU in the remote array is
undergoing the forced parity
correction.
Check the pool LU status of
the remote array and retry
after waiting for a while.
9576
x0A4
94
The S-VOL in the remote array
exceeded the total allowable
maximum number of TCE and
SnapShot pairs.
Check the status of the
remote array. In addition,
delete unnecessary pairs of
the remote array.
9576
x0A5
94
The TCE pair status of the S-VOL in
the remote array is PSUE.
Check the TCE pair status of
the remote array.
9576
x0A6
94
The TCE pair status of the S-VOL in
the remote array is PFUS.
Check the TCE pair status of
the remote array.
9576
x0A7
94
The TCE pair status of the S-VOL in
the remote array is PSUS (no
reading or writing allowed).
Check the TCE pair status of
the remote array.
9576
x0A8
94
The TCE pair status of the S-VOL in
the remote array is SSWS
(including SSWS(R)).
Check the TCE pair status of
the remote array.
9576
x0A9
94
The TCE pair status of the S-VOL in
the remote array is SMPL.
Check the TCE pair status of
the remote array.
9576
x0AA
94
The TCE pair status of the S-VOL in
the remote array is PSUS.
Check the TCE pair status of
the remote array.
Table 3-5: Sense Codes (Continued)
Sense
code
Detailed
code
Sub
code
Error contents
Recommended Action
Summary of Contents for AMS 2000 Series
Page 6: ...vi Table of Contents Hitachi AMS 2000 Family Command Control Interface CCI Reference Guide ...
Page 244: ...4 18 Command options Hitachi AMS 2000 Family Command Control Interface CCI Reference Guide ...
Page 261: ...1 Hitachi AMS 2000 Family Command Control Interface CCI Reference Guide ...