Maintenance log and tracing functions
3–39
Hitachi AMS 2000 Family Command Control Interface (CCI) Reference Guide
9609
x0A7
94
The TCE pair status of the S-VOL in
the remote array is PSUS (no
reading or writing allowed).
Check the TCE pair status of
the remote array.
9609
x0A8
94
The TCE pair status of the S-VOL in
the remote array is SSWS
(including SSWS(R)).
Check the TCE pair status of
the remote array.
9609
x0A9
94
The TCE pair status of the S-VOL in
the remote array is SMPL.
Check the TCE pair status of
the remote array.
9609
x0AA
94
The TCE pair status of the S-VOL in
the remote array is PSUS.
Check the TCE pair status of
the remote array.
9609
x0AB
94
The TCE pair status of the S-VOL in
the remote array is not SMPL.
Check the TCE pair status of
the remote array.
9609
x0B4
94
The S-VOL in the remote array
does not exist on the default
owner controller and, at the same
time, the special processing
cannot be continued.
Check the status of the
remote array and retry after
waiting for a while.
9609
x0B5
94
The S-VOL in the remote array
does not exist on the default
owner controller and, at the same
time, an ownership of LU change
for it has been started.
Check the status of the
remote array and retry after
waiting for a while.
9609
x0B6
94
The S-VOL in the remote array
does not exist on the default
owner controller and it has started
an ownership of LU change.
Check the status of the
remote array and retry after
waiting for a while.
9609
x0B7
94
The S-VOL in the remote array
does not exist on the default
owner controller and, at the same
time, an ownership of LU to be
changed is blocked.
Check the status of the
remote array and retry after
waiting for a while.
9609
x0B8
94
The S-VOL in the remote array
cannot change an ownership of LU
and, at the same time, it is using
the sequential buffer.
Check the status of the
remote array and retry after
waiting for a while.
9609
x0B9
94
The S-VOL in the remote array
cannot change an ownership of LU
temporarily.
Retry after waiting for a
while.
9609
x0BA
94
The S-VOL in the remote array
cannot change an ownership of LU
and, at the same time, it has
pinned data.
Contact the service
personnel.
9609
x0BB
94
The S-VOL in the remote array
cannot change an ownership of LU
temporarily.
Retry after waiting for a
while.
9609
x0BC
94
The S-VOL in the remote array
cannot change an ownership of LU
temporarily.
Retry after waiting for a
while.
Table 3-5: Sense Codes (Continued)
Sense
code
Detailed
code
Sub
code
Error contents