9
3.5 Installer Parameters Table
3.5.1 Category 1 - Room Unit Settings
Note
Remember to always press the green
button to confirm that you want to store your new Installer
Set-Up setting. To exit the Installer Mode press the
or
button.
Parameter
Parameter
No.
Factory Default Setting
Optional Setting
Category 1 Parameters – Room Unit Settings
Display Description
Display Description
AM-PM / 24hr
Display
1:CL
24
24 hr clock display
format
12
12 hr – AM/PM clock display
format
Reset Time/ Temp
Program
2:rP
1
Time / Temp profile
set to factory default
Changes to 0 when
one of the time/temp
profiles are changed
0
Time / Temperature are as
programmed
To restore the factory profile set
to 1
Auto Summer/
Winter Time
Change
3:tC
1
Auto Summer/
Winter Time Change
Enabled
0
Auto Summer/Winter Time Change
Disabled
LCD Backlighting
5:bL
1
Backlighting Enable
0
Backlighting Disabled
Upper Temp Limit
6:uL
35
35°C Upper Temp.
Limit
21 to
34
21°C to 34°C adjustment in 1°C
steps
Lower Temp Limit
7:LL
5
5°C Lower Temp.
Limit
5 to 21 6°C to 21°C adjustment in 1°C
steps
Optimisation
Note: This
parameter will
not function
with the System
Controller.
8:OP
0
Optimisation
Disabled
1
Optimisation Enabled
DO NOT CHANGE
Temperature
Offset
12:tO
0
No temperature
offset
-3 to
+3
-3°C to +3°C adjustment in 0.1°C
steps
Proportional Band
Width
Note: This
function is for
use with the
extension system
only. It will not
function with
the System
Controller alone
13:Pb
1.5
Proportional band of
1.5 degrees
1.6 to
3.0
1.6°C to 3.0°C adjustment in 0.1°C
steps
Reset Parameters
to Factory
Defaults
19:FS
1
All settings at factory
defaults
Changes to 0 when
one of the parameter
is changed
0
Settings are as modified above
To restore the factory profile set
to 1
Installation and Operation Manual